Design and characterization of the Flat-Field Calibration of the NectarCAM Camera

The NectarCAM flat-field flasher is a calibration device designed for the camera that will equip the Medium-Sized Telescopes (MSTs) of the northern site of the Cherenkov Telescope Array Observatory (CTAO). Positioned in the centre of the MST dish, 16 meters in front of the camera, the flasher emits short (FWHM ${\approx}\,5$ ns), uniform (2-4%) light pulses to illuminate the entire focal plane. Accurate calibration is crucial for the optimal operation of the NectarCAM, ensuring precise gain computation and mitigating differences in light-collection efficiency of the pixels of the camera. Using the flat-field flasher, two informations are obtained : the pixel gain and the relative efficiency between pixels. In addition, the flasher is used to probe the dynamic range over which the camera operates effectively. In this study, we report on the performance characterisation of the flat-field flasher using a dedicated test bench. We report on the results of tests conducted on several flasher units, evaluating their reliability. Furthermore, we describe how the flat-field coefficients are applied within the camera to ensure uniformity of response of few percent level across all 1855 pixels. As the deployment of the first MST at the CTAO northern site is scheduled for 2027, this work represents a significant contribution to the collaboration's efforts to finalize camera calibration systems.

Authors

Institutions

Publication Details

Published
2025-09-24
DOI
https://doi.org/10.22323/1.501.0759
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and characterization of the Flat-Field Calibration of the NectarCAM Camera

Federica Bradascio, Arthur Mikhno, P. Jean, K. Pressard et al.
Optical measurement and interference techniques
article

Design and characterization of the Flat-Field Calibration of the NectarCAM Camera

Federica Bradascio, Arthur Mikhno, P. Jean, K. Pressard, V. Marandon, F. Brun, J. Biteau, J.-P. Lenain, Quentin Luce, Hossam Boutalha, Georges Vasileiadis, Justine Devin, Patrick Brun, Armelle Jardin-Blicq, Michaël Josselin
article en

Abstract

The NectarCAM flat-field flasher is a calibration device designed for the camera that will equip the Medium-Sized Telescopes (MSTs) of the northern site of the Cherenkov Telescope Array Observatory (CTAO). Positioned in the centre of the MST dish, 16 meters in front of the camera, the flasher emits short (FWHM ${\approx}\,5$ ns), uniform (2-4%) light pulses to illuminate the entire focal plane. Accurate calibration is crucial for the optimal operation of the NectarCAM, ensuring precise gain computation and mitigating differences in light-collection efficiency of the pixels of the camera. Using the flat-field flasher, two informations are obtained : the pixel gain and the relative efficiency between pixels. In addition, the flasher is used to probe the dynamic range over which the camera operates effectively. In this study, we report on the performance characterisation of the flat-field flasher using a dedicated test bench. We report on the results of tests conducted on several flasher units, evaluating their reliability. Furthermore, we describe how the flat-field coefficients are applied within the camera to ensure uniformity of response of few percent level across all 1855 pixels. As the deployment of the first MST at the CTAO northern site is scheduled for 2027, this work represents a significant contribution to the collaboration's efforts to finalize camera calibration systems.

Institut Universitaire de France (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Laboratoire Univers et Particules de Montpellier (FR), Laboratoire de Physique Nucléaire et de Hautes Énergies (FR), Laboratoire de Physique des deux infinis Bordeaux (FR), CEA Paris-Saclay (FR), Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (FR), Institut de Recherche sur les Lois Fondamentales de l'Univers (FR), Institut de Recherche en Astrophysique et Planétologie (FR)
Openalex Percentile: Top 74%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.