Immediate Load Carriage Improves Core Temperature but Not Skin Temperatures When Wearing Wet Clothing in Mild Cold Air

IntroductionMembers of the military are regularly exposed to austere environmental conditions that may create clothing saturation in cold conditions. This study sought to determine whether immediate ruck initiation is superior in maintaining rectal temperature (<i>T<sub>re</sub></i>), improving skin temperatures, and augmenting thermal comfort compared with remaining static and/or delayed ruck initiation when wet in cold air.MethodsEleven healthy adults (10 males and 1 female, 26±9 y old, 22.5±8.6% body fat) participated in this study. Volunteers were immersed in warm water (34.0±0.3°C) before entering the cold chamber (5.3±0.4°C) and began immediately rucking (IR) or stood statically for 60 min (Static) before rucking (delayed rucking [DR]) for 60 min.ResultsIR initiation was superior in elevating <i>T<sub>re</sub></i> compared with Static at 20 min (37.6±0.4 vs 37.3±0.2°C, <i>P</i>=0.033), 40 min (37.9±0.4 vs 37.5±0.2°C, <i>P</i>=0.012), and 60 min (37.9±0.4 vs 37.6±0.3°C, <i>P</i>=0.016). IR <i>T<sub>re</sub></i> was also greater than DR at 40 min (37.9±0.4 vs 37.4±0.5°C, <i>P</i>=0.002) and 60 min of wet-cold exposure (37.9±0.4 vs 37.5±0.5°C, <i>P</i><0.001). Consequently, IR tended to improve thermal sensation ratings compared with both DR and Static. Yet, IR was no more sufficient in overcoming wet-cold decrements in skin temperatures than Static, especially at the finger (<i>P</i>>0.05).ConclusionsCompared with DR and Static, IR is effective at elevating deep body temperature and improving thermal perceptions but is significantly less effective at improving wet-cold skin temperatures compared with Static.

Authors

Institutions

Publication Details

Journal
Wilderness and Environmental Medicine
Published
2025-09-24
DOI
https://doi.org/10.1177/10806032251376323
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Immediate Load Carriage Improves Core Temperature but Not Skin Temperatures When Wearing Wet Clothing in Mild Cold Air

Dina M. Pitsas, Afton D. Seeley, Andrew M. Greenfield, Billie K. Alba et al.
Wilderness and Environmental Medicine
Thermoregulation and physiological responses
article

Immediate Load Carriage Improves Core Temperature but Not Skin Temperatures When Wearing Wet Clothing in Mild Cold Air

Dina M. Pitsas, Afton D. Seeley, Andrew M. Greenfield, Billie K. Alba, John W. Castellani, Phillip O. Bodurtha, Catherine O’Brien, MariaLena A. Shaw
article en

Abstract

IntroductionMembers of the military are regularly exposed to austere environmental conditions that may create clothing saturation in cold conditions. This study sought to determine whether immediate ruck initiation is superior in maintaining rectal temperature (<i>T<sub>re</sub></i>), improving skin temperatures, and augmenting thermal comfort compared with remaining static and/or delayed ruck initiation when wet in cold air.MethodsEleven healthy adults (10 males and 1 female, 26±9 y old, 22.5±8.6% body fat) participated in this study. Volunteers were immersed in warm water (34.0±0.3°C) before entering the cold chamber (5.3±0.4°C) and began immediately rucking (IR) or stood statically for 60 min (Static) before rucking (delayed rucking [DR]) for 60 min.ResultsIR initiation was superior in elevating <i>T<sub>re</sub></i> compared with Static at 20 min (37.6±0.4 vs 37.3±0.2°C, <i>P</i>=0.033), 40 min (37.9±0.4 vs 37.5±0.2°C, <i>P</i>=0.012), and 60 min (37.9±0.4 vs 37.6±0.3°C, <i>P</i>=0.016). IR <i>T<sub>re</sub></i> was also greater than DR at 40 min (37.9±0.4 vs 37.4±0.5°C, <i>P</i>=0.002) and 60 min of wet-cold exposure (37.9±0.4 vs 37.5±0.5°C, <i>P</i><0.001). Consequently, IR tended to improve thermal sensation ratings compared with both DR and Static. Yet, IR was no more sufficient in overcoming wet-cold decrements in skin temperatures than Static, especially at the finger (<i>P</i>>0.05).ConclusionsCompared with DR and Static, IR is effective at elevating deep body temperature and improving thermal perceptions but is significantly less effective at improving wet-cold skin temperatures compared with Static.

Wilderness and Environmental MedicineVol. 37(1)
U.S. Army Research Institute of Environmental Medicine (US), Oak Ridge Associated Universities (US), Oak Ridge Institute for Science and Education
Openalex Percentile: Top 67%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.