Serial connection of 48-cell alkaline electrolysis stacks

Power supply cost significantly impacts the economic feasibility and the balance of plant in alkaline electrolysis, and since these costs are mainly driven by the rated current, increasing system voltage can improve cost efficiency. Voltage can be raised by using longer stacks or connecting shorter stacks in series; however, stack length is limited by stray currents and mechanical constraints, making serial connection of short stacks a promising approach. This study experimentally investigates a 200 V alkaline water electrolysis (AWE) system comprising two 48-cell stacks, tested individually and in series, focusing on current efficiency, specific energy consumption (SEC), and stray current behavior under different operating conditions and DC grounding schemes. The adoption of a serial connection was operationally feasible: individual stacks reached current efficiencies above 95 %, while the series configuration showed a modest reduction, with SEC increasing by less than 5 % once current exceeded 50 % of nominal load. At low currents, however, external stray currents accounted for up to 30 % of the supply current, leading to efficiency losses of around 10%–20% compared to single-stack operation. Grounding the second stack increased stray current magnitude due to the elevated potential gradient between the first stack and ground. Higher electrolyte flow improved gas removal and reduced cell voltages by about 1 %, but also slightly increased stray currents through outlet hoses. Theoretical estimates of gas-induced conductivity losses underestimated actual stray current magnitudes, likely due to faster gas removal than assumed. • Serial connection of two 48-cell AWE stacks validated at 200 V. • Serial operation shows minimal loss vs. single stack operation. • External stray currents cause main losses at low operating currents. • Higher temperature improves current efficiency and lowers SEC. • Grounding and hose design critical for stray current reduction.

Authors

Institutions

Publication Details

Journal
Journal of Power Sources
Published
2025-09-24
DOI
https://doi.org/10.1016/j.jpowsour.2025.238382
Citations
7
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
3.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Serial connection of 48-cell alkaline electrolysis stacks

Vesa Ruuskanen, Markku Niemelä, Jero Ahola, Rainer Küngas et al.
7 citations
Journal of Power Sources
Hybrid Renewable Energy Systems
3.72
article

Serial connection of 48-cell alkaline electrolysis stacks

Vesa Ruuskanen, Markku Niemelä, Jero Ahola, Rainer Küngas, Pertti Kauranen, Toni Viinanen, Paul Sonnabend, Simo Vuorsalo, Matti Kauhanen
article en
7 citations

Abstract

Power supply cost significantly impacts the economic feasibility and the balance of plant in alkaline electrolysis, and since these costs are mainly driven by the rated current, increasing system voltage can improve cost efficiency. Voltage can be raised by using longer stacks or connecting shorter stacks in series; however, stack length is limited by stray currents and mechanical constraints, making serial connection of short stacks a promising approach. This study experimentally investigates a 200 V alkaline water electrolysis (AWE) system comprising two 48-cell stacks, tested individually and in series, focusing on current efficiency, specific energy consumption (SEC), and stray current behavior under different operating conditions and DC grounding schemes. The adoption of a serial connection was operationally feasible: individual stacks reached current efficiencies above 95 %, while the series configuration showed a modest reduction, with SEC increasing by less than 5 % once current exceeded 50 % of nominal load. At low currents, however, external stray currents accounted for up to 30 % of the supply current, leading to efficiency losses of around 10%–20% compared to single-stack operation. Grounding the second stack increased stray current magnitude due to the elevated potential gradient between the first stack and ground. Higher electrolyte flow improved gas removal and reduced cell voltages by about 1 %, but also slightly increased stray currents through outlet hoses. Theoretical estimates of gas-induced conductivity losses underestimated actual stray current magnitudes, likely due to faster gas removal than assumed. • Serial connection of two 48-cell AWE stacks validated at 200 V. • Serial operation shows minimal loss vs. single stack operation. • External stray currents cause main losses at low operating currents. • Higher temperature improves current efficiency and lowers SEC. • Grounding and hose design critical for stray current reduction.

Journal of Power SourcesVol. 659
ABB (Finland) (FI), Hydrogenics (Belgium) (BE), Lappeenranta-Lahti University of Technology (FI), Aalto University (FI)
Openalex Percentile: Top 7%
Hybrid Renewable Energy Systems
3.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.