Investigation of V-down staggered rib roughness for improved solar air heater efficiency: An experimental analysis

An investigational examination was conducted to examine the effect of V-down aligned gap with staggered rib roughness on the heat dissipation rate and frictional behaviour of airflow in a rectangular solar air heater (SAH) duct. The roughness geometry comprised both variable and fixed geometrical parameters: the variable parameters included the relative rib pitch (p/e) from 6 to 14, staggering ratio (p’/p) from 0.2 to 0.8, and relative size of staggered rib (r/g) from 0.25 to 2. Meanwhile, the fixed parameter included a relative gap breadth (g/e) of 4, number of gaps (Ng) of 3, and relative height of rib (e/D h ) of 0.0433. Span of Reynolds number (Re) varies from 4000 to 15,000 throughout this study. The geometrical parameters were analysed and optimized to evaluate the overall impact of roughness configuration on SAH performance. Results indicates that the maximum Nusselt number and friction factor were increased by up to 2.16 and 2.74 times, respectively compared to a smooth surface particularly at optimal configuration of p/e of 10, p’/p of 0.4, r/g of 1, e/D h of 0.043, g/e of 4, and Ng of 3. The thermal-hydraulic performance (THP) parameter of the proposed V-rib geometry was compared with existing V-rib geometries to validate the overall behaviour of the present rib roughness. Furthermore, correlations in terms of the heat transfer function R (e + ), and the roughness function G (e + ) were developed to predict the performance of the present V-rib roughness.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy
Published
2025-09-24
DOI
https://doi.org/10.1177/09576509251382737
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of V-down staggered rib roughness for improved solar air heater efficiency: An experimental analysis

Atul Lanjewar, Piyush Kumar Jain, Jitendra Singh, Anoop Pratap Singh
Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy
Heat Transfer Mechanisms
article

Investigation of V-down staggered rib roughness for improved solar air heater efficiency: An experimental analysis

Atul Lanjewar, Piyush Kumar Jain, Jitendra Singh, Anoop Pratap Singh
article en

Abstract

An investigational examination was conducted to examine the effect of V-down aligned gap with staggered rib roughness on the heat dissipation rate and frictional behaviour of airflow in a rectangular solar air heater (SAH) duct. The roughness geometry comprised both variable and fixed geometrical parameters: the variable parameters included the relative rib pitch (p/e) from 6 to 14, staggering ratio (p’/p) from 0.2 to 0.8, and relative size of staggered rib (r/g) from 0.25 to 2. Meanwhile, the fixed parameter included a relative gap breadth (g/e) of 4, number of gaps (Ng) of 3, and relative height of rib (e/D h ) of 0.0433. Span of Reynolds number (Re) varies from 4000 to 15,000 throughout this study. The geometrical parameters were analysed and optimized to evaluate the overall impact of roughness configuration on SAH performance. Results indicates that the maximum Nusselt number and friction factor were increased by up to 2.16 and 2.74 times, respectively compared to a smooth surface particularly at optimal configuration of p/e of 10, p’/p of 0.4, r/g of 1, e/D h of 0.043, g/e of 4, and Ng of 3. The thermal-hydraulic performance (THP) parameter of the proposed V-rib geometry was compared with existing V-rib geometries to validate the overall behaviour of the present rib roughness. Furthermore, correlations in terms of the heat transfer function R (e + ), and the roughness function G (e + ) were developed to predict the performance of the present V-rib roughness.

Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and EnergyVol. 239(8)
Bansal Institute Of Research Technology & Science (IN), Institute of Science and Technology, Maulana Azad National Institute of Technology (IN)
Openalex Percentile: Top 73%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of V-down staggered rib roughness for improved solar air heater efficiency: An experimental analysis — Atul Lanjewar, Piyush Kumar Jain, et al. · Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy (2025) | TGRS Research Map | TGRS