Estimation of Compression Depth During CPR Using FMCW Radar with Deep Convolutional Neural Network

Effective Cardiopulmonary Resuscitation (CPR) requires precise chest compression depth, but current out-of-hospital monitoring technologies face limitations. This study introduces a method using frequency-modulated continuous-wave (FMCW) radar to remotely and accurately monitor chest compressions. FMCW radar captures range, Doppler, and angular data, and we utilize micro-Doppler signatures for detailed motion analysis. By integrating Doppler shifts over time, chest displacement is estimated. We compare a regression model based on maximum Doppler frequency with deep convolutional neural networks (DCNNs) trained on spectrograms generated via short-time Fourier transform (STFT) and the Wigner-Ville distribution (WVD). The regression model achieved a root mean square error (RMSE) of 0.535 cm. The STFT-based DCNN improved accuracy with an RMSE of 0.505 cm, while the WVD-based DCNN achieved the best performance with an RMSE of 0.447 cm, representing an 11.5% improvement over the STFT-based DCNN. These findings highlight the potential of combining FMCW radar and deep learning to provide accurate, real-time chest compression depth measurement during CPR, supporting the development of advanced, non-contact monitoring systems for emergency medical response.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-09-24
DOI
https://doi.org/10.3390/s25195947
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of Compression Depth During CPR Using FMCW Radar with Deep Convolutional Neural Network

Stephen Gyung Won Lee, Hyoun‐Joong Kong, Ki Jeong Hong, Youngwook Kim et al.
Sensors
Cardiac Arrest and Resuscitation
article

Estimation of Compression Depth During CPR Using FMCW Radar with Deep Convolutional Neural Network

Stephen Gyung Won Lee, Hyoun‐Joong Kong, Ki Jeong Hong, Youngwook Kim, In-Soo Choi
article en

Abstract

Effective Cardiopulmonary Resuscitation (CPR) requires precise chest compression depth, but current out-of-hospital monitoring technologies face limitations. This study introduces a method using frequency-modulated continuous-wave (FMCW) radar to remotely and accurately monitor chest compressions. FMCW radar captures range, Doppler, and angular data, and we utilize micro-Doppler signatures for detailed motion analysis. By integrating Doppler shifts over time, chest displacement is estimated. We compare a regression model based on maximum Doppler frequency with deep convolutional neural networks (DCNNs) trained on spectrograms generated via short-time Fourier transform (STFT) and the Wigner-Ville distribution (WVD). The regression model achieved a root mean square error (RMSE) of 0.535 cm. The STFT-based DCNN improved accuracy with an RMSE of 0.505 cm, while the WVD-based DCNN achieved the best performance with an RMSE of 0.447 cm, representing an 11.5% improvement over the STFT-based DCNN. These findings highlight the potential of combining FMCW radar and deep learning to provide accurate, real-time chest compression depth measurement during CPR, supporting the development of advanced, non-contact monitoring systems for emergency medical response.

SensorsVol. 25(19)
Seoul National University (KR), Sogang University (KR)
Openalex Percentile: Top 61%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.