Ultrathin Fe2O3 nanosheet-enhanced molecularly imprinted photoelectrochemical sensor for ultrasensitive detection of imidacloprid pesticide
Herein, a novel molecularly imprinted photoelectrochemical (MIP-PEC) sensor was fabricated through integrating the ultrathin nanosheets of Fe 2 O 3 (Fe 2 O 3 NSs) with molecular imprinting technology for the ultrasensitive detection of imidacloprid (IMD). Impressively, the two-dimensional Fe 2 O 3 NSs was synthesized on an indium‑tin oxide (ITO) substrate by electrodeposition. Benefiting from its narrow bandgap and large specific surface area, the photogenerated charge separation efficiency of Fe 2 O 3 NSs (∼ 600 μA) was remarkably enhanced compared to that of the commercial Fe 2 O 3 nanoparticles (∼150 μA), which significantly improved the sensitivity of the developed MIP-PEC sensor. Furthermore, the electropolymerization technique was used to form a molecularly imprinted polymer film of IMD on the surface of Fe 2 O 3 NSs/ITO, substantially increased the detection selectivity of the proposed sensor. As a result, the designed MIP-PEC sensor successfully achieved ultrasensitive and specific as well as reliable detection of IMD with a broad linear response (5 nM ∼ 120 μM), low detection limit (1.02 nM) and long storage time (the signal only decreased by 5.03 % after 4 weeks of storage). The recoveries and relative standard deviation (RSD) for the determination of IMD in fruits and environmental water samples by the obtained MIP-PEC were in the range of 92.0 % ∼ 108.0 % and 3.2 % ∼ 4.9 % respectively, validating its field-applicability. Obviously, this work established a novel paradigm for synergistic enhancement of the analysis performance of PEC through integration of the advanced photosensitive materials with molecular imprinting technology. • Electrodeposited ultrathin Fe₂O₃ NSs on ITO exhibited 2.75 cm 2 surface area and 1.68 eV bandgap. • Direct electropolymerization of IMD-MIP on Fe₂O₃ NSs to create precise cavities for selective imidacloprid recognition. • Wide linear range, low detection limit, and higher sensitivity of this proposed sensor for imidacloprid was observed. • The sensor demonstrated excellent stability and reliability, achieving spiked recovery in actual samples.
Authors
- Yiting Wang (ORCID: https://orcid.org/0000-0001-9536-7339)
- Kui Yao (ORCID: https://orcid.org/0000-0001-5875-4815)
- Jun Shen (ORCID: https://orcid.org/0000-0002-9403-7140)
- Yuwei Zhao
- Qiue Cao (ORCID: https://orcid.org/0000-0002-6272-9986)
- Hao Li (ORCID: https://orcid.org/0000-0001-6946-4362)
- Ruiying Zhang (ORCID: https://orcid.org/0000-0001-7042-1554)
- Xin Zhu Sang
Publication Details
- Journal
- Journal of Electroanalytical Chemistry
- Published
- 2025-09-24
- DOI
- https://doi.org/10.1016/j.jelechem.2025.119494
- Primary Topic
- Advanced biosensing and bioanalysis techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00