MDFSBP: A multi-perspective differential feature space framework for estimating blood pressure using photoplethysmography (PPG)

Continuous and accurate blood pressure (BP) monitoring is critical for personalized hypertension management. However, most existing methods focus on absolute BP estimation, with limited attention to BP changes. To address this limitation, we propose a novel framework named Multi-Perspective Differential Feature Space (MDFSBP) for cuffless BP estimation using photoplethysmography (PPG) signals. MDFSBP extracts three perspective differential features: time-based and points-of-interest features, frequency-domain features, and physiological statistical features. Then, an adaptive Multi-Perspective Differential Feature Mapping Module (MDFMM) integrates reconstruction regularization, trend-aware classification, and self-weighted contrastive learning to enhance feature representation and strengthen the association between features and BP changes. Finally, an AutoML-based regression pipeline automates model optimization, improving predictive accuracy and deployment efficiency. To better test the model’s capability in capturing BP changes, we introduce a novel abnormality-aware classification metric. We demonstrate BP estimation performance over state-of-the-art (SOTA) methods on both the Mindray and MIMIC datasets. On the Mindray dataset, the model achieves a regression error of 0.17 ± 5.17 mmHg for SBP and 0.05 ± 3.29 mmHg for DBP, with classification accuracy and F1-score reaching 85.25% and 87.50%, respectively. On the MIMIC dataset, it achieves −0.09 ± 5.70 mmHg for SBP and 0.12 ± 4.27 mmHg for DBP, with the classification accuracy and F1-score of 72.84% and 70.66%, respectively. These results highlight the effectiveness, robustness, and generalizability of the proposed framework for non-invasive, real-time, and continuous BP monitoring in both clinical and wearable healthcare systems. • Propose MDFSBP for cuffless BP estimation using PPG. • Build differential features in time, frequency and statistics. • MDFMM integrates reconstruction, contrastive, and trend tasks. • AutoML regression enables efficient model selection and deployment. • Method outperforms existing approaches on two datasets.

Authors

Institutions

Publication Details

Journal
Medicine in Novel Technology and Devices
Published
2025-09-24
DOI
https://doi.org/10.1016/j.medntd.2025.100407
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MDFSBP: A multi-perspective differential feature space framework for estimating blood pressure using photoplethysmography (PPG)

Chenbin Ma, Guanglei Zhang, Haonan Zhang
1 citations
Medicine in Novel Technology and Devices
Non-Invasive Vital Sign Monitoring
0.67
article

MDFSBP: A multi-perspective differential feature space framework for estimating blood pressure using photoplethysmography (PPG)

Chenbin Ma, Guanglei Zhang, Haonan Zhang
article en
1 citations

Abstract

Continuous and accurate blood pressure (BP) monitoring is critical for personalized hypertension management. However, most existing methods focus on absolute BP estimation, with limited attention to BP changes. To address this limitation, we propose a novel framework named Multi-Perspective Differential Feature Space (MDFSBP) for cuffless BP estimation using photoplethysmography (PPG) signals. MDFSBP extracts three perspective differential features: time-based and points-of-interest features, frequency-domain features, and physiological statistical features. Then, an adaptive Multi-Perspective Differential Feature Mapping Module (MDFMM) integrates reconstruction regularization, trend-aware classification, and self-weighted contrastive learning to enhance feature representation and strengthen the association between features and BP changes. Finally, an AutoML-based regression pipeline automates model optimization, improving predictive accuracy and deployment efficiency. To better test the model’s capability in capturing BP changes, we introduce a novel abnormality-aware classification metric. We demonstrate BP estimation performance over state-of-the-art (SOTA) methods on both the Mindray and MIMIC datasets. On the Mindray dataset, the model achieves a regression error of 0.17 ± 5.17 mmHg for SBP and 0.05 ± 3.29 mmHg for DBP, with classification accuracy and F1-score reaching 85.25% and 87.50%, respectively. On the MIMIC dataset, it achieves −0.09 ± 5.70 mmHg for SBP and 0.12 ± 4.27 mmHg for DBP, with the classification accuracy and F1-score of 72.84% and 70.66%, respectively. These results highlight the effectiveness, robustness, and generalizability of the proposed framework for non-invasive, real-time, and continuous BP monitoring in both clinical and wearable healthcare systems. • Propose MDFSBP for cuffless BP estimation using PPG. • Build differential features in time, frequency and statistics. • MDFMM integrates reconstruction, contrastive, and trend tasks. • AutoML regression enables efficient model selection and deployment. • Method outperforms existing approaches on two datasets.

Medicine in Novel Technology and DevicesVol. 28
Beihang University (CN)
Openalex Percentile: Top 26%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.