Electrocatalytic Oxygen Reduction Activity of <i>E. coli</i> O157:H7 under H <sub>2</sub> O <sub>2</sub> Stress for Biosensing Application

The electrocatalytic activity of environmental stressed bacteria is closely related to their cellular activity. In this study, the electrocatalytic activity toward oxygen reduction of <i>E. coli</i> O157:H7 under physical, chemical, and biological environmental stress was explored through cyclic voltammetry (CV). Interestingly, when <i>E. coli</i> O157:H7 was stimulated under 5 mM H<sub>2</sub>O<sub>2</sub> stress for 30 min, a distinct reduction peak and a reduction current at the mA level could be observed, indicating that the electrocatalytic oxygen reduction ability of <i>E. coli</i> O157:H7 was significantly enhanced. Then, the electrocatalytic mechanism of the <i>E. coli</i> O157:H7 under H<sub>2</sub>O<sub>2</sub> stress was systematically analyzed from the growth dynamics, microscopic morphology, oxidative stress response, and metabolomics, and the electron transfer mechanism of its respiratory chain was clarified. Furthermore, metabolic pathway enrichment analysis showed that tricarboxylic acid (TCA) cycle and respiratory chain promoted NADH and ATP synthesis. The L-fucose synthesis indicated that ubiquinone (UQ, the core electron carrier of biocatalytic reaction) pathway was upregulated, enhancing bacterial cell catalytic activity and electron transport efficiency. Moreover, an electrochemical sensor utilizing H<sub>2</sub>O<sub>2</sub> stress was developed for <i>E. coli</i> O157:H7 detection. The sensor demonstrated exceptional performance, displaying a maximum variation of 9.34 times in the ECL signal under H<sub>2</sub>O<sub>2</sub> stress and achieving a remarkably low detection limit of 10 CFU <i>E. coli</i> O157:H7 in 1 mL sample volume. This study provides a new solution for the sensitive screening of electrochemically active bacteria, with broad application prospects.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-09-24
DOI
https://doi.org/10.1021/acssensors.5c02329
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrocatalytic Oxygen Reduction Activity of E. coli O157:H7 under H 2 O 2 Stress for Biosensing Application

Mengjuan Li, Qi Yan, Yuanjian Liu, Ke Liu et al.
1 citations
ACS Sensors
Electrochemical sensors and biosensors
0.73
article

Electrocatalytic Oxygen Reduction Activity of E. coli O157:H7 under H 2 O 2 Stress for Biosensing Application

Mengjuan Li, Qi Yan, Yuanjian Liu, Ke Liu, Panpan Liu, Fengyang Wang, Xiaohui Xiong
article en
1 citations

Abstract

The electrocatalytic activity of environmental stressed bacteria is closely related to their cellular activity. In this study, the electrocatalytic activity toward oxygen reduction of <i>E. coli</i> O157:H7 under physical, chemical, and biological environmental stress was explored through cyclic voltammetry (CV). Interestingly, when <i>E. coli</i> O157:H7 was stimulated under 5 mM H<sub>2</sub>O<sub>2</sub> stress for 30 min, a distinct reduction peak and a reduction current at the mA level could be observed, indicating that the electrocatalytic oxygen reduction ability of <i>E. coli</i> O157:H7 was significantly enhanced. Then, the electrocatalytic mechanism of the <i>E. coli</i> O157:H7 under H<sub>2</sub>O<sub>2</sub> stress was systematically analyzed from the growth dynamics, microscopic morphology, oxidative stress response, and metabolomics, and the electron transfer mechanism of its respiratory chain was clarified. Furthermore, metabolic pathway enrichment analysis showed that tricarboxylic acid (TCA) cycle and respiratory chain promoted NADH and ATP synthesis. The L-fucose synthesis indicated that ubiquinone (UQ, the core electron carrier of biocatalytic reaction) pathway was upregulated, enhancing bacterial cell catalytic activity and electron transport efficiency. Moreover, an electrochemical sensor utilizing H<sub>2</sub>O<sub>2</sub> stress was developed for <i>E. coli</i> O157:H7 detection. The sensor demonstrated exceptional performance, displaying a maximum variation of 9.34 times in the ECL signal under H<sub>2</sub>O<sub>2</sub> stress and achieving a remarkably low detection limit of 10 CFU <i>E. coli</i> O157:H7 in 1 mL sample volume. This study provides a new solution for the sensitive screening of electrochemically active bacteria, with broad application prospects.

ACS SensorsVol. 10(10)
Nanjing Tech University (CN), Horological Research Institute of Light Industry (CN)
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.