Electrocatalytic Oxygen Reduction Activity of <i>E. coli</i> O157:H7 under H <sub>2</sub> O <sub>2</sub> Stress for Biosensing Application
The electrocatalytic activity of environmental stressed bacteria is closely related to their cellular activity. In this study, the electrocatalytic activity toward oxygen reduction of <i>E. coli</i> O157:H7 under physical, chemical, and biological environmental stress was explored through cyclic voltammetry (CV). Interestingly, when <i>E. coli</i> O157:H7 was stimulated under 5 mM H<sub>2</sub>O<sub>2</sub> stress for 30 min, a distinct reduction peak and a reduction current at the mA level could be observed, indicating that the electrocatalytic oxygen reduction ability of <i>E. coli</i> O157:H7 was significantly enhanced. Then, the electrocatalytic mechanism of the <i>E. coli</i> O157:H7 under H<sub>2</sub>O<sub>2</sub> stress was systematically analyzed from the growth dynamics, microscopic morphology, oxidative stress response, and metabolomics, and the electron transfer mechanism of its respiratory chain was clarified. Furthermore, metabolic pathway enrichment analysis showed that tricarboxylic acid (TCA) cycle and respiratory chain promoted NADH and ATP synthesis. The L-fucose synthesis indicated that ubiquinone (UQ, the core electron carrier of biocatalytic reaction) pathway was upregulated, enhancing bacterial cell catalytic activity and electron transport efficiency. Moreover, an electrochemical sensor utilizing H<sub>2</sub>O<sub>2</sub> stress was developed for <i>E. coli</i> O157:H7 detection. The sensor demonstrated exceptional performance, displaying a maximum variation of 9.34 times in the ECL signal under H<sub>2</sub>O<sub>2</sub> stress and achieving a remarkably low detection limit of 10 CFU <i>E. coli</i> O157:H7 in 1 mL sample volume. This study provides a new solution for the sensitive screening of electrochemically active bacteria, with broad application prospects.
Authors
- Mengjuan Li (ORCID: https://orcid.org/0000-0002-5692-9287)
- Qi Yan (ORCID: https://orcid.org/0000-0002-0533-227X)
- Yuanjian Liu (ORCID: https://orcid.org/0000-0002-1241-6930)
- Ke Liu (ORCID: https://orcid.org/0000-0002-5090-8186)
- Panpan Liu (ORCID: https://orcid.org/0000-0002-7447-7026)
- Fengyang Wang
- Xiaohui Xiong
Institutions
- Nanjing Tech University (CN)
- Horological Research Institute of Light Industry (CN)
Publication Details
- Journal
- ACS Sensors
- Published
- 2025-09-24
- DOI
- https://doi.org/10.1021/acssensors.5c02329
- Citations
- 1
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.73