Does Q.Clear Processing Change PET Ratios? Quantitative Evidence Using BTXBrain-DAT

<b>Introduction</b>: Bayesian penalized likelihood (BPL) reconstruction algorithms, commercially implemented as Q.Clear (GE Healthcare), enhance image quality but may alter quantitative metrics. The impact of BPL on dopamine transporter (DAT) PET quantification, including ratios, remains unclear. This study investigates whether Q.Clear processing alters key metrics such as specific binding ratios (SBRs) and interregional ratios. <b>Methods</b>: We retrospectively analyzed 170 paired F-18 FP-CIT PET datasets reconstructed with conventional 3D-OSEM (baseline-DICOM) and Q.Clear (Q.Clear-DICOM). Quantification was performed using BTXBrain-DAT (Brightonix Imaging), yielding 57 specific binding ratios (SBRs), three asymmetry indices, and nine interregional ratios. Paired statistical tests, Bland-Altman plots, and reproducibility checks were conducted. Visual reads by two nuclear medicine physicians were also compared between datasets. <b>Results</b>: Q.Clear processing significantly altered all quantitative metrics (<i>p</i> < 0.001). SBR values changed in all 57 regions, with most high-uptake regions showing an increase and low-uptake regions showing a decrease. Striatal and caudate asymmetry indices showed significant differences (<i>p</i> < 0.0001), whereas the putamen index remained stable. All interregional ratios differed significantly, although Bland-Altman analysis indicated relative stability for ratios compared with asymmetric indices. BTXBrain-DAT showed perfect reproducibility on repeat analysis, and visual interpretation was unaffected by reconstruction method. <b>Conclusions</b>: Q.Clear (BPL) reconstruction substantially influences F-18 FP-CIT PET quantification, including ratios and asymmetry indices, while leaving visual interpretation unchanged. These findings highlight the need for caution when using image enhancement functions for quantitative analysis, particularly in clinical studies involving low-uptake regions or multicenter data comparisons.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2025-09-24
DOI
https://doi.org/10.3390/brainsci15101036
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does Q.Clear Processing Change PET Ratios? Quantitative Evidence Using BTXBrain-DAT

Ji Yeon Chung, Ari Chong, Jung‐Min Ha
Brain Sciences
Medical Imaging Techniques and Applications
article

Does Q.Clear Processing Change PET Ratios? Quantitative Evidence Using BTXBrain-DAT

Ji Yeon Chung, Ari Chong, Jung‐Min Ha
article en

Abstract

<b>Introduction</b>: Bayesian penalized likelihood (BPL) reconstruction algorithms, commercially implemented as Q.Clear (GE Healthcare), enhance image quality but may alter quantitative metrics. The impact of BPL on dopamine transporter (DAT) PET quantification, including ratios, remains unclear. This study investigates whether Q.Clear processing alters key metrics such as specific binding ratios (SBRs) and interregional ratios. <b>Methods</b>: We retrospectively analyzed 170 paired F-18 FP-CIT PET datasets reconstructed with conventional 3D-OSEM (baseline-DICOM) and Q.Clear (Q.Clear-DICOM). Quantification was performed using BTXBrain-DAT (Brightonix Imaging), yielding 57 specific binding ratios (SBRs), three asymmetry indices, and nine interregional ratios. Paired statistical tests, Bland-Altman plots, and reproducibility checks were conducted. Visual reads by two nuclear medicine physicians were also compared between datasets. <b>Results</b>: Q.Clear processing significantly altered all quantitative metrics (<i>p</i> < 0.001). SBR values changed in all 57 regions, with most high-uptake regions showing an increase and low-uptake regions showing a decrease. Striatal and caudate asymmetry indices showed significant differences (<i>p</i> < 0.0001), whereas the putamen index remained stable. All interregional ratios differed significantly, although Bland-Altman analysis indicated relative stability for ratios compared with asymmetric indices. BTXBrain-DAT showed perfect reproducibility on repeat analysis, and visual interpretation was unaffected by reconstruction method. <b>Conclusions</b>: Q.Clear (BPL) reconstruction substantially influences F-18 FP-CIT PET quantification, including ratios and asymmetry indices, while leaving visual interpretation unchanged. These findings highlight the need for caution when using image enhancement functions for quantitative analysis, particularly in clinical studies involving low-uptake regions or multicenter data comparisons.

Brain SciencesVol. 15(10)
Chosun University (KR)
Openalex Percentile: Top 61%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Does Q.Clear Processing Change PET Ratios? Quantitative Evidence Using BTXBrain-DAT — Ji Yeon Chung, Ari Chong, et al. · Brain Sciences (2025) | TGRS Research Map | TGRS