Evaluation of color stability and material surface stability of different types of clear aligners under curcumin staining in vitro

Aesthetics play a crucial role in patients' choice of orthodontic clear aligners, as poor color stability can compromise their appearance during wear. This study aimed to evaluate the color and surface stability of different types of orthodontic clear aligners exposed to various concentrations of curcumin solutions in vitro. Four types of clear aligners (Invisalign, Angelalign, Spark, and Dreve), along with non-thermoformed Dreve film, were cut into 5 mm × 5 mm squares and immersed in curcumin solutions of different concentrations and a control solution. The concentrations were determined based on the curcumin content in curry. Anhydrous ethanol was used as the solvent, which may influence surface properties and color stability and partially simulating damage caused by alcohol consumption or bacterial metabolites. After immersion for 12 h and 7 days, the squares were ultrasonically cleaned, and color changes were measured using a colorimeter, then converted to National Bureau of Standards (NBS) units. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to observe surface characteristics before and after staining. After 12 h of immersion in 10 µg/ml solutions, all samples except the Dreve film exhibited at least an "Appreciable: marked change," with Angelalign showing a more pronounced color alteration. After 7 days of immersion, most materials displayed color changes ranging from "Much: extremely marked change" to "Very much: change to other colors." Across all concentrations and time points, Invisalign aligners exhibited significantly higher ΔE* values than Dreve (P < 0.05). Although SEM and AFM results were not entirely consistent, both indicated that PU-based aligners were more susceptible to surface morphology changes than PET-G-based aligners. Enhancing the aesthetic color stability of orthodontic materials could contribute to improved clinical outcomes.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2025-09-24
DOI
https://doi.org/10.1186/s12903-025-06225-6
Citations
1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of color stability and material surface stability of different types of clear aligners under curcumin staining in vitro

Wen Liao, Ketai He, Yao Yang, Mingjie Xu
1 citations
BMC Oral Health
Dental materials and restorations
1.68
article

Evaluation of color stability and material surface stability of different types of clear aligners under curcumin staining in vitro

Wen Liao, Ketai He, Yao Yang, Mingjie Xu
article en
1 citations

Abstract

Aesthetics play a crucial role in patients' choice of orthodontic clear aligners, as poor color stability can compromise their appearance during wear. This study aimed to evaluate the color and surface stability of different types of orthodontic clear aligners exposed to various concentrations of curcumin solutions in vitro. Four types of clear aligners (Invisalign, Angelalign, Spark, and Dreve), along with non-thermoformed Dreve film, were cut into 5 mm × 5 mm squares and immersed in curcumin solutions of different concentrations and a control solution. The concentrations were determined based on the curcumin content in curry. Anhydrous ethanol was used as the solvent, which may influence surface properties and color stability and partially simulating damage caused by alcohol consumption or bacterial metabolites. After immersion for 12 h and 7 days, the squares were ultrasonically cleaned, and color changes were measured using a colorimeter, then converted to National Bureau of Standards (NBS) units. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to observe surface characteristics before and after staining. After 12 h of immersion in 10 µg/ml solutions, all samples except the Dreve film exhibited at least an "Appreciable: marked change," with Angelalign showing a more pronounced color alteration. After 7 days of immersion, most materials displayed color changes ranging from "Much: extremely marked change" to "Very much: change to other colors." Across all concentrations and time points, Invisalign aligners exhibited significantly higher ΔE* values than Dreve (P < 0.05). Although SEM and AFM results were not entirely consistent, both indicated that PU-based aligners were more susceptible to surface morphology changes than PET-G-based aligners. Enhancing the aesthetic color stability of orthodontic materials could contribute to improved clinical outcomes.

BMC Oral HealthVol. 25(1)
Sichuan University (CN), Stomatology Hospital (CN)
Natural Science Foundation of Sichuan Province
Openalex Percentile: Top 15%
Dental materials and restorations
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.