Impact of Extreme Temperatures on Hemostatic Gauze Using Thromboelastography

IntroductionHemorrhage control in austere environments is challenging, particularly for wounds that are not amenable to tourniquets. Hemostatic gauzes are crucial in such settings, but their efficacy may be compromised by suboptimal storage conditions, including extreme temperatures, where discoloration has been observed. This study evaluated the impact of extreme temperature exposure on the efficacy of hemostatic gauze using thromboelastography.MethodsBlood from 30 healthy adults was diluted by 30% with hetastarch to mimic trauma-induced coagulopathy. Kerlix and QuikClot Combat Gauze stored for 3 weeks in cold (-10°C), hot (70°C), and room-temperature (22°C) environments were compared in the thromboelastography parameters of <i>R</i> (time to initiation of clot formation), <i>K</i> (clot amplification), <i>α</i> angle (clot formation rate), and <i>MA</i> (maximum amplitude of clot).ResultsCompared with whole blood, diluted blood had weaker clots with slower clot-formation kinetics (<i>MA</i>=58 vs 43 mm, <i>P</i><0.0001; <i>K</i>=2.6 vs 4.0 min, <i>P</i><0.0001; <i>α</i> angle=55 vs 47 degrees, <i>P</i><0.0003) but faster clot initiation times (<i>R</i>=8.7 vs 7.1 min, <i>P</i><0.0001). Addition of either gauze shortened clot initiation times (Kerlix: 7.1 vs 5.0 min, <i>P</i><0.0001; QuikClot Combat Gauze: 7.1 vs 2.7 min, <i>P</i><0.0001), with QuikClot Combat Gauze significantly shortening <i>R</i> compared with Kerlix. Reductions in <i>R</i> values were consistent across temperature extremes (<i>P</i><0.05). The other parameters were consistently unaffected (<i>P</i>>0.05).ConclusionsThis in vitro laboratory study demonstrated that hemostatic gauze retained its ability to initiate clotting in vitro even after prolonged exposure to temperature extremes.

Authors

Institutions

Publication Details

Journal
Wilderness and Environmental Medicine
Published
2025-09-24
DOI
https://doi.org/10.1177/10806032251376307
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Extreme Temperatures on Hemostatic Gauze Using Thromboelastography

Taylor DesRosiers, Sean Stuart, Matthew Jordan, Brittany A. Ockenfels
Wilderness and Environmental Medicine
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

Impact of Extreme Temperatures on Hemostatic Gauze Using Thromboelastography

Taylor DesRosiers, Sean Stuart, Matthew Jordan, Brittany A. Ockenfels
article en

Abstract

IntroductionHemorrhage control in austere environments is challenging, particularly for wounds that are not amenable to tourniquets. Hemostatic gauzes are crucial in such settings, but their efficacy may be compromised by suboptimal storage conditions, including extreme temperatures, where discoloration has been observed. This study evaluated the impact of extreme temperature exposure on the efficacy of hemostatic gauze using thromboelastography.MethodsBlood from 30 healthy adults was diluted by 30% with hetastarch to mimic trauma-induced coagulopathy. Kerlix and QuikClot Combat Gauze stored for 3 weeks in cold (-10°C), hot (70°C), and room-temperature (22°C) environments were compared in the thromboelastography parameters of <i>R</i> (time to initiation of clot formation), <i>K</i> (clot amplification), <i>α</i> angle (clot formation rate), and <i>MA</i> (maximum amplitude of clot).ResultsCompared with whole blood, diluted blood had weaker clots with slower clot-formation kinetics (<i>MA</i>=58 vs 43 mm, <i>P</i><0.0001; <i>K</i>=2.6 vs 4.0 min, <i>P</i><0.0001; <i>α</i> angle=55 vs 47 degrees, <i>P</i><0.0003) but faster clot initiation times (<i>R</i>=8.7 vs 7.1 min, <i>P</i><0.0001). Addition of either gauze shortened clot initiation times (Kerlix: 7.1 vs 5.0 min, <i>P</i><0.0001; QuikClot Combat Gauze: 7.1 vs 2.7 min, <i>P</i><0.0001), with QuikClot Combat Gauze significantly shortening <i>R</i> compared with Kerlix. Reductions in <i>R</i> values were consistent across temperature extremes (<i>P</i><0.05). The other parameters were consistently unaffected (<i>P</i>>0.05).ConclusionsThis in vitro laboratory study demonstrated that hemostatic gauze retained its ability to initiate clotting in vitro even after prolonged exposure to temperature extremes.

Wilderness and Environmental MedicineVol. 37(1)
Naval Medical Center Portsmouth (US), Naval Facilities Engineering Systems Command (US), Group Health Centre (CA), Navy and Marine Corps Force Health Protection Command (US)
Openalex Percentile: Top 70%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.