Extending the depth range in energy-dispersive X-ray stress analysis by simultaneous multi-detector data acquisition in equatorial scattering geometry

A scattering geometry for depth-resolved energy-dispersive X-ray stress analysis on polycrystalline materials is introduced. Via simultaneous data acquisition during a sin<sup>2</sup> ψ measurement using two detectors arranged in the horizontal diffraction plane, it aims to extend the accessible information depth to the free surface as well as deeper material zones. While data acquisition with the first detector takes place in a symmetrical configuration with regard to the incident and exit angles, α<sub>i</sub> and α<sub>e</sub>, respectively, the second detector runs in an asymmetrical mode, defined by α<sub>i</sub> < α<sub>e</sub>. Therefore, the scattering vectors assigned to the two diffraction geometries run in different tilt planes during a χ scan of the sample performed in the Eulerian cradle. Treatment of the data recorded in the asymmetric diffraction mode requires modifications of the fundamental equation of X-ray stress analysis, which are discussed using the example of measurements performed on a unidirectionally ground ferritic steel sample.

Authors

Institutions

Publication Details

Journal
Journal of Applied Crystallography
Published
2025-09-24
DOI
https://doi.org/10.1107/s1600576725007599
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extending the depth range in energy-dispersive X-ray stress analysis by simultaneous multi-detector data acquisition in equatorial scattering geometry

Daniel Apel, Christoph Genzel, Mirko Boin, Manuela Klaus
Journal of Applied Crystallography
Advanced X-ray and CT Imaging
article

Extending the depth range in energy-dispersive X-ray stress analysis by simultaneous multi-detector data acquisition in equatorial scattering geometry

Daniel Apel, Christoph Genzel, Mirko Boin, Manuela Klaus
article en

Abstract

A scattering geometry for depth-resolved energy-dispersive X-ray stress analysis on polycrystalline materials is introduced. Via simultaneous data acquisition during a sin<sup>2</sup> ψ measurement using two detectors arranged in the horizontal diffraction plane, it aims to extend the accessible information depth to the free surface as well as deeper material zones. While data acquisition with the first detector takes place in a symmetrical configuration with regard to the incident and exit angles, α<sub>i</sub> and α<sub>e</sub>, respectively, the second detector runs in an asymmetrical mode, defined by α<sub>i</sub> < α<sub>e</sub>. Therefore, the scattering vectors assigned to the two diffraction geometries run in different tilt planes during a χ scan of the sample performed in the Eulerian cradle. Treatment of the data recorded in the asymmetric diffraction mode requires modifications of the fundamental equation of X-ray stress analysis, which are discussed using the example of measurements performed on a unidirectionally ground ferritic steel sample.

Journal of Applied CrystallographyVol. 58(5)
Helmholtz-Zentrum Berlin für Materialien und Energie (DE)
Universität Kassel
Openalex Percentile: Top 75%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extending the depth range in energy-dispersive X-ray stress analysis by simultaneous multi-detector data acquisition in equatorial scattering geometry — Daniel Apel, Christoph Genzel, et al. · Journal of Applied Crystallography (2025) | TGRS Research Map | TGRS