Characterization of diffraction efficiency for X-ray analyzer crystals using a laboratory-based primary diffraction photon method

X-ray analyzer crystals are core components in monochromatic X-ray sources. Their diffraction efficiency (<i>η</i>) critically determines key beam parameters like flux density. Current efficiency measurements primarily rely on synchrotron sources, facing challenges of limited access and high cost. We present a laboratory method using primary diffraction photons to eliminate systematic errors from detector resolution limitations. Based on this principle, a calibration system achieved 22.2<i>%</i>±2.5<i>%</i> peak <i>η</i> for Si(220) at 4.51 keV. This approach and system provide reliable support for calibrating the diffraction efficiency of various analyzer crystals and can be deployed for rapid screening of crystals in X-ray calibration facilities.

Authors

Publication Details

Journal
Applied Optics
Published
2025-09-24
DOI
https://doi.org/10.1364/ao.575231
Primary Topic
X-ray Diffraction in Crystallography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of diffraction efficiency for X-ray analyzer crystals using a laboratory-based primary diffraction photon method

Lizhi Sheng, pengfei qiang, Yue Li, Yong-qing Yan et al.
Applied Optics
X-ray Diffraction in Crystallography
article

Characterization of diffraction efficiency for X-ray analyzer crystals using a laboratory-based primary diffraction photon method

Lizhi Sheng, pengfei qiang, Yue Li, Yong-qing Yan, renzhou zheng
article en

Abstract

X-ray analyzer crystals are core components in monochromatic X-ray sources. Their diffraction efficiency (<i>η</i>) critically determines key beam parameters like flux density. Current efficiency measurements primarily rely on synchrotron sources, facing challenges of limited access and high cost. We present a laboratory method using primary diffraction photons to eliminate systematic errors from detector resolution limitations. Based on this principle, a calibration system achieved 22.2<i>%</i>±2.5<i>%</i> peak <i>η</i> for Si(220) at 4.51 keV. This approach and system provide reliable support for calibrating the diffraction efficiency of various analyzer crystals and can be deployed for rapid screening of crystals in X-ray calibration facilities.

Applied OpticsVol. 64(30)
Openalex Percentile: Top 80%
X-ray Diffraction in Crystallography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.