Synergistic Voluntary Muscle Signal Characteristic Analysis and Comparison of OPM-MMG and sEMG

Optically pumped magnetometers (OPMs) are quantum sensors enabling novel biomagnetic measurements. Integrating OPM-based magnetomyography (MMG) with conventional surface electromyography (sEMG) offers enhanced functional assessment of voluntary muscle activity (VMA), with promising applications in human-machine interaction, neuromuscular diagnosis, and rehabilitation. However, the synergistic spontaneous muscle signals exhibit highly complex interference phases, while both sEMG and MMG are characterized by nonstationary randomness and temporal variability. These properties pose significant challenges to the quantitative comparison and consistency validation of sEMG and MMG signal features. In this study, for the first time, a high-precision, real-time synchronous measurement system combining sEMG and OPM-MMG was proposed to capture compound muscle action potentials (CMAPs) produced by synergistic skeletal muscle activation. In the proposed system, the magnetically compatible electrode configuration and the modulation-based time-delay compensation technique ensure spatiotemporally aligned conditions for multimodal signal acquisition. Moreover, the multivariate feature analysis method optimized by the Thresholded Gaussian Filtering-Amplitude Probability Distribution Function (TGF-APDF) overcomes the inherent noise and complexity associated with direct comparisons of raw signals. Experimental results reveal a minimal latency difference of 0.0018 (± 0.0046) s and amplitude probability distribution deviation under 5% (p < 0.01) between sEMG and MMG. Meanwhile, significant differences and variability are observed in dominant modal distributions across channels. These findings demonstrate complementary strengths of the two modalities: sEMG excels in temporal resolution, while MMG provides superior spatial resolution. This work advances the multimodal assessment of muscle function, offering new insights for neuromuscular disease evaluation and motivating future applications leveraging OPM-MMG technology.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3613905
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synergistic Voluntary Muscle Signal Characteristic Analysis and Comparison of OPM-MMG and sEMG

Yang Gao, Xiaolin Ning, Han Wu, Hang Yu
IEEE Transactions on Instrumentation and Measurement
Muscle activation and electromyography studies
article

Synergistic Voluntary Muscle Signal Characteristic Analysis and Comparison of OPM-MMG and sEMG

Yang Gao, Xiaolin Ning, Han Wu, Hang Yu
article en

Abstract

Optically pumped magnetometers (OPMs) are quantum sensors enabling novel biomagnetic measurements. Integrating OPM-based magnetomyography (MMG) with conventional surface electromyography (sEMG) offers enhanced functional assessment of voluntary muscle activity (VMA), with promising applications in human-machine interaction, neuromuscular diagnosis, and rehabilitation. However, the synergistic spontaneous muscle signals exhibit highly complex interference phases, while both sEMG and MMG are characterized by nonstationary randomness and temporal variability. These properties pose significant challenges to the quantitative comparison and consistency validation of sEMG and MMG signal features. In this study, for the first time, a high-precision, real-time synchronous measurement system combining sEMG and OPM-MMG was proposed to capture compound muscle action potentials (CMAPs) produced by synergistic skeletal muscle activation. In the proposed system, the magnetically compatible electrode configuration and the modulation-based time-delay compensation technique ensure spatiotemporally aligned conditions for multimodal signal acquisition. Moreover, the multivariate feature analysis method optimized by the Thresholded Gaussian Filtering-Amplitude Probability Distribution Function (TGF-APDF) overcomes the inherent noise and complexity associated with direct comparisons of raw signals. Experimental results reveal a minimal latency difference of 0.0018 (± 0.0046) s and amplitude probability distribution deviation under 5% (p < 0.01) between sEMG and MMG. Meanwhile, significant differences and variability are observed in dominant modal distributions across channels. These findings demonstrate complementary strengths of the two modalities: sEMG excels in temporal resolution, while MMG provides superior spatial resolution. This work advances the multimodal assessment of muscle function, offering new insights for neuromuscular disease evaluation and motivating future applications leveraging OPM-MMG technology.

IEEE Transactions on Instrumentation and Measurement
Beihang University (CN)
Openalex Percentile: Top 75%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.