Comparative analysis of harmonic analysis for the improvement of PQ using DVR, D-STATCOM and UPQC

The idea behind custom power is to use cutting-edge power electronics-based devices that can be linked to the disruptive load in series or parallel to compensate for various Power Quality (PQ) difficulties. The goal of this research project is to use various specialized power devices to reduce harmonics in induction type furnace. The effectivity of each device in reducing voltage and current harmonics in non- sinusoidal conditions is evaluated. The PQ analyzer is used to record the experimental readings. The simulink model of an induction type furnace has been created, and its performance has been compared to real-time data collected from active induction furnaces at several steel plants. Finally, the results obtained demonstrate that Total Harmonic Distortion (THD) of an induction boiler can be significantly reduced by using these devices. The developed model's performance is consistent with the operational features of the industrial induction furnance.

Authors

Institutions

Publication Details

Published
2025-05-15
DOI
https://doi.org/10.1109/ic2e365635.2025.11167577
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of harmonic analysis for the improvement of PQ using DVR, D-STATCOM and UPQC

Akhil Gupta, B. Deepraj Singh, Naveen Kumar Sharma
Engineering Applied Research
article

Comparative analysis of harmonic analysis for the improvement of PQ using DVR, D-STATCOM and UPQC

Akhil Gupta, B. Deepraj Singh, Naveen Kumar Sharma
article en

Abstract

The idea behind custom power is to use cutting-edge power electronics-based devices that can be linked to the disruptive load in series or parallel to compensate for various Power Quality (PQ) difficulties. The goal of this research project is to use various specialized power devices to reduce harmonics in induction type furnace. The effectivity of each device in reducing voltage and current harmonics in non- sinusoidal conditions is evaluated. The PQ analyzer is used to record the experimental readings. The simulink model of an induction type furnace has been created, and its performance has been compared to real-time data collected from active induction furnaces at several steel plants. Finally, the results obtained demonstrate that Total Harmonic Distortion (THD) of an induction boiler can be significantly reduced by using these devices. The developed model's performance is consistent with the operational features of the industrial induction furnance.

Punjab Technical University (IN)
Openalex Percentile: Top 73%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative analysis of harmonic analysis for the improvement of PQ using DVR, D-STATCOM and UPQC — Akhil Gupta, B. Deepraj Singh, et al. · (2025) | TGRS Research Map | TGRS