Multiplexing Post-Filter of Inter-Frame Correlation Minimum Variance for Ultrasound Imaging

Minimum variance (MV) beamformer is widely studied in ultrasound imaging due to its high resolution. However, its inadequacy in algorithm complexity and contrast limits its practical application. In this paper, by constructing a covariance matrix and optimizing the covariance matrix with cross-correlation variables, we designed a multiplexing post-filter of the transmit inter-frame correlation minimum variance algorithm (ICMVMPF) to improve the image contrast and complex. The experiments of cyst phantom indicates that the average resolution of ICMVMPF can improved 50.23% than that of DAS, and the contrast of ICMVMPF can increased 15.19dB and 13.4dB than that of delay-and-sum (DAS) and MV in the depth of 67mm. The adult cardiac imaging demonstrates that the proposed ICMVMPF has better contrast and clearer heart valve architecture compared with the traditional DAS beamformer.

Authors

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/icipmc66319.2025.11170696
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiplexing Post-Filter of Inter-Frame Correlation Minimum Variance for Ultrasound Imaging

Chongchong Guo, Yin Wu, Zheng Zhu, Li Lei et al.
Ultrasound Imaging and Elastography
article

Multiplexing Post-Filter of Inter-Frame Correlation Minimum Variance for Ultrasound Imaging

Chongchong Guo, Yin Wu, Zheng Zhu, Li Lei, Xiao Hui Li
article en

Abstract

Minimum variance (MV) beamformer is widely studied in ultrasound imaging due to its high resolution. However, its inadequacy in algorithm complexity and contrast limits its practical application. In this paper, by constructing a covariance matrix and optimizing the covariance matrix with cross-correlation variables, we designed a multiplexing post-filter of the transmit inter-frame correlation minimum variance algorithm (ICMVMPF) to improve the image contrast and complex. The experiments of cyst phantom indicates that the average resolution of ICMVMPF can improved 50.23% than that of DAS, and the contrast of ICMVMPF can increased 15.19dB and 13.4dB than that of delay-and-sum (DAS) and MV in the depth of 67mm. The adult cardiac imaging demonstrates that the proposed ICMVMPF has better contrast and clearer heart valve architecture compared with the traditional DAS beamformer.

Shenzhen Institutes of Advanced Technology (CN), Mindray (China) (CN)
Openalex Percentile: Top 61%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multiplexing Post-Filter of Inter-Frame Correlation Minimum Variance for Ultrasound Imaging — Chongchong Guo, Yin Wu, et al. · (2025) | TGRS Research Map | TGRS