Design and Performance Evaluation of Superconducting Wire-Wound Gradiometers for SQUID-Based Ultralow-Field MRI

In recent years, ultralow-field (ULF) magnetic resonance imaging (MRI) has shown its potential in portable MRI System. As the superconducting magnet is replaced by permanent magnet or electronic magnet, the weight and the cost of the system could be effectively reduced. However, the low main field strength leads to low signal-to-noise ratio. Superconducting quantum interference devices (SQUIDs), as the most sensitive magnetic flux sensors known to date, have been employed in the system to measure the weak magnetic signal. Since a bare SQUID chip has limited magnetic field resolution and insufficient adaptability to the practical environment, a flux transformer, which consists of a pickup coil and input coil, is typically introduced and coupled with the SQUID. For example, in our Al shielded ULF MRI system, second-order axial gradiometers are applied as pickup coils to suppress the external magnetic field noise, thus, enhance the signal-to-noise ratio (SNR). However, the geometrical parameters of gradiometers significantly affect their performance, which includes the ability to suppress the ambient noise and the sensitivity to the signal. In this paper, we first present geometrical requirements of the second-order gradiometers to ensure that the designed configurations have equal noise suppression ability. Then, we acquire a general expression of the sensitivity pattern of a second-order gradiometer through mathematical calculation. Through the above two steps, we propose a design and evaluation method for second-order SQUID-based gradiometers for ULF MRI. Based on this method, an asymmetric configuration wire-wound gradiometer with optimized loop numbers is proposed and applied in our ULF MRI system. Compared to the conventional symmetric configuration gradiometer, the proposed one achieved approximately a 1.5-fold improvement in sensitivity to the signal for a shallow imaging slice while maintaining similar noise suppression capabilities. This improvement offers a broader imaging area and higher measurement accuracy for the ULF MRI system. All code and data used in this study are openly available to ensure reproducibility, following IEEE reproducibility guidelines.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3613917
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Performance Evaluation of Superconducting Wire-Wound Gradiometers for SQUID-Based Ultralow-Field MRI

Hui Dong, Guofeng Zhang, Longqing Qiu, Jun Wu et al.
IEEE Transactions on Instrumentation and Measurement
Atomic and Subatomic Physics Research
article

Design and Performance Evaluation of Superconducting Wire-Wound Gradiometers for SQUID-Based Ultralow-Field MRI

Hui Dong, Guofeng Zhang, Longqing Qiu, Jun Wu, Liangliang Rong, Quan Tao, Xue Ren, Zhizhong Wan
article en

Abstract

In recent years, ultralow-field (ULF) magnetic resonance imaging (MRI) has shown its potential in portable MRI System. As the superconducting magnet is replaced by permanent magnet or electronic magnet, the weight and the cost of the system could be effectively reduced. However, the low main field strength leads to low signal-to-noise ratio. Superconducting quantum interference devices (SQUIDs), as the most sensitive magnetic flux sensors known to date, have been employed in the system to measure the weak magnetic signal. Since a bare SQUID chip has limited magnetic field resolution and insufficient adaptability to the practical environment, a flux transformer, which consists of a pickup coil and input coil, is typically introduced and coupled with the SQUID. For example, in our Al shielded ULF MRI system, second-order axial gradiometers are applied as pickup coils to suppress the external magnetic field noise, thus, enhance the signal-to-noise ratio (SNR). However, the geometrical parameters of gradiometers significantly affect their performance, which includes the ability to suppress the ambient noise and the sensitivity to the signal. In this paper, we first present geometrical requirements of the second-order gradiometers to ensure that the designed configurations have equal noise suppression ability. Then, we acquire a general expression of the sensitivity pattern of a second-order gradiometer through mathematical calculation. Through the above two steps, we propose a design and evaluation method for second-order SQUID-based gradiometers for ULF MRI. Based on this method, an asymmetric configuration wire-wound gradiometer with optimized loop numbers is proposed and applied in our ULF MRI system. Compared to the conventional symmetric configuration gradiometer, the proposed one achieved approximately a 1.5-fold improvement in sensitivity to the signal for a shallow imaging slice while maintaining similar noise suppression capabilities. This improvement offers a broader imaging area and higher measurement accuracy for the ULF MRI system. All code and data used in this study are openly available to ensure reproducibility, following IEEE reproducibility guidelines.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Shanghai Institute of Microsystem and Information Technology (CN)
Openalex Percentile: Top 79%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.