Does patient-based data monitoring allow us to reconsider the relationship between IQC and EQA?

Currently, there is no accepted standard practice for determining the frequency of EQA challenge. The challenge frequency has evolved based on history and local requirements. However, EQA frequency should be based on identifying patient risks caused by poorly performing laboratories, methods, or processes in any phase of the total testing cycle. The role of IQC is to ensure result consistency from day to day and to halt reporting of results if there is an analytical failure. Historically, both activities have been based on synthetic control material. With the development of patient-based approaches to IQC and EQA, it is possible to continuously monitor analytical systems using the same patient parameter, usually the mean or median. These techniques can provide laboratories with additional information to reduce patient risk. There are limitations of Patient-Based Quality Assurance (PBQA), fundamentally the lack of middleware and connection of the analyzers to the EQA provider. It cannot be used to monitor the success of harmonization/standardization of assays to a reference measurement procedure. But the use of patient-based approaches offers an opportunity to reconsider how EQA can be undertaken and the relationship between IQC and EQA. If PBRTQC and PBQA could be implemented to provide daily peer group comparisons, then method-specific bias could be identified quickly by a laboratory. If this could be supplemented with a commutable, reference value assigned EQA program, then monitoring harmonization/standardization of assays to a reference measurement procedure could be achieved.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2025-09-23
DOI
https://doi.org/10.1515/cclm-2025-1133
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does patient-based data monitoring allow us to reconsider the relationship between IQC and EQA?

Tony Badrick, Derek Holzhauser, John Sioufi
Clinical Chemistry and Laboratory Medicine (CCLM)
Hemodynamic Monitoring and Therapy
article

Does patient-based data monitoring allow us to reconsider the relationship between IQC and EQA?

Tony Badrick, Derek Holzhauser, John Sioufi
article en

Abstract

Currently, there is no accepted standard practice for determining the frequency of EQA challenge. The challenge frequency has evolved based on history and local requirements. However, EQA frequency should be based on identifying patient risks caused by poorly performing laboratories, methods, or processes in any phase of the total testing cycle. The role of IQC is to ensure result consistency from day to day and to halt reporting of results if there is an analytical failure. Historically, both activities have been based on synthetic control material. With the development of patient-based approaches to IQC and EQA, it is possible to continuously monitor analytical systems using the same patient parameter, usually the mean or median. These techniques can provide laboratories with additional information to reduce patient risk. There are limitations of Patient-Based Quality Assurance (PBQA), fundamentally the lack of middleware and connection of the analyzers to the EQA provider. It cannot be used to monitor the success of harmonization/standardization of assays to a reference measurement procedure. But the use of patient-based approaches offers an opportunity to reconsider how EQA can be undertaken and the relationship between IQC and EQA. If PBRTQC and PBQA could be implemented to provide daily peer group comparisons, then method-specific bias could be identified quickly by a laboratory. If this could be supplemented with a commutable, reference value assigned EQA program, then monitoring harmonization/standardization of assays to a reference measurement procedure could be achieved.

Clinical Chemistry and Laboratory Medicine (CCLM)Vol. 64(2)
Royal College of Pathologists of Australasia (AU)
Openalex Percentile: Top 59%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Does patient-based data monitoring allow us to reconsider the relationship between IQC and EQA? — Tony Badrick, Derek Holzhauser, et al. · Clinical Chemistry and Laboratory Medicine (CCLM) (2025) | TGRS Research Map | TGRS