An ICH Q14‐Guided AQbD Framework for the Development of an HPLC Method: Analysis of Siponimod Fumarate and Its Impurities

Siponimod fumarate (SIP), a potent selective S1P receptor modulator, has emerged as a critical therapeutic agent in the treatment of multiple sclerosis. Recognizing the increasing regulatory demands for robust impurity profiling and method reliability, this study reports the development and optimization of an HPLC method for the simultaneous determination of SIP and its related impurities in both bulk drug substance and tablet dosage forms. The method was developed within an Analytical Quality by Design (AQbD) framework, guided by ICH Q14 principles, ensuring a systematic and risk-based approach throughout the analytical lifecycle. Chromatographic separation necessary for resolving critical impurities was achieved on an XSelect HSS T3 column (150 mm × 4.6 mm, 3.5 µm) using a stepped gradient elution program with 0.1% perchloric acid in water and acetonitrile as the mobile phases. Optimal separation conditions, identified through the AQbD process to meet stringent performance criteria, were determined at a column temperature of 42.5°C, a flow rate of 1.4 mL min<sup>-1</sup>, and UV detection at 212 nm. The method performance was rigorously evaluated through accuracy profiles, confirming both its precision and trueness across the targeted concentration range. In parallel, as part of a holistic method characterization, environmental sustainability was assessed using comprehensive greenness metrics, whereas its practical applicability was further substantiated using the Blue Applicability Grade Index (BAGI) and the Red-Green-Blue 12 (RGB12) algorithms. This approach not only bridges the gap created by the absence of an official pharmacopoeial monograph for SIP but also offers a robust, well-characterized, and sustainable platform for pharmaceutical quality control, aligning method development with both regulatory performance needs and environmental awareness.

Authors

Institutions

Publication Details

Journal
Electrophoresis
Published
2025-09-23
DOI
https://doi.org/10.1002/elps.70039
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ICH Q14‐Guided AQbD Framework for the Development of an HPLC Method: Analysis of Siponimod Fumarate and Its Impurities

Mona H. Alhalafi, Mostafa M. Eraqi, Ayman M. Algohary, Afnan Altwala et al.
Electrophoresis
Analytical Methods in Pharmaceuticals
article

An ICH Q14‐Guided AQbD Framework for the Development of an HPLC Method: Analysis of Siponimod Fumarate and Its Impurities

Mona H. Alhalafi, Mostafa M. Eraqi, Ayman M. Algohary, Afnan Altwala, Ahmed M. Ibrahim
article en

Abstract

Siponimod fumarate (SIP), a potent selective S1P receptor modulator, has emerged as a critical therapeutic agent in the treatment of multiple sclerosis. Recognizing the increasing regulatory demands for robust impurity profiling and method reliability, this study reports the development and optimization of an HPLC method for the simultaneous determination of SIP and its related impurities in both bulk drug substance and tablet dosage forms. The method was developed within an Analytical Quality by Design (AQbD) framework, guided by ICH Q14 principles, ensuring a systematic and risk-based approach throughout the analytical lifecycle. Chromatographic separation necessary for resolving critical impurities was achieved on an XSelect HSS T3 column (150 mm × 4.6 mm, 3.5 µm) using a stepped gradient elution program with 0.1% perchloric acid in water and acetonitrile as the mobile phases. Optimal separation conditions, identified through the AQbD process to meet stringent performance criteria, were determined at a column temperature of 42.5°C, a flow rate of 1.4 mL min<sup>-1</sup>, and UV detection at 212 nm. The method performance was rigorously evaluated through accuracy profiles, confirming both its precision and trueness across the targeted concentration range. In parallel, as part of a holistic method characterization, environmental sustainability was assessed using comprehensive greenness metrics, whereas its practical applicability was further substantiated using the Blue Applicability Grade Index (BAGI) and the Red-Green-Blue 12 (RGB12) algorithms. This approach not only bridges the gap created by the absence of an official pharmacopoeial monograph for SIP but also offers a robust, well-characterized, and sustainable platform for pharmaceutical quality control, aligning method development with both regulatory performance needs and environmental awareness.

ElectrophoresisVol. 46(23)
Majmaah University (SA), National Research Centre (EG), Egyptian Government (EG)
Openalex Percentile: Top 71%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.