Calculating <scp>SF<sub>6</sub></scp> Leak Rate in Linear Accelerators From Digital Pressure Logs

Sulfur Hexafluoride, one of the most potent greenhouse gases, is used in radiation oncology as a dielectric in linear accelerator waveguides. Given the high global warming potential of SF<sub>6</sub>, its use is heavily regulated, and possible leaks should be proactively monitored. Truebeam Linac diagnostic log files record SF<sub>6</sub> pressure metrics every 2 h. These log files were parsed, and the high time resolution pressure data were studied across a fleet of 15 Varian Truebeam Linear Accelerators for a 1 year period. Average SF<sub>6</sub> leak rates were low, but highly variable (8.6 g/year/Linac, std dev 17.7 g). Pressure fluctuation due to temperature change was found to be a similar magnitude to real SF<sub>6</sub> losses over months. Leak rates calculated from pressure loss were significantly below those reported in the literature and manufacturer specifications. Pressure fluctuation proportional to temperature change caused by Linac use makes SF<sub>6</sub> pressure an unreliable metric to sample infrequently if the aim is to detect small leaks. A novel method for calculating leak rate using high sample rate log files mitigates this effect, giving a more accurate measurement.

Authors

Institutions

Publication Details

Journal
Journal of Medical Imaging and Radiation Oncology
Published
2025-09-23
DOI
https://doi.org/10.1111/1754-9485.70025
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculating SF6 Leak Rate in Linear Accelerators From Digital Pressure Logs

James Everitt
Journal of Medical Imaging and Radiation Oncology
Advanced Radiotherapy Techniques
article

Calculating SF6 Leak Rate in Linear Accelerators From Digital Pressure Logs

James Everitt
article en

Abstract

Sulfur Hexafluoride, one of the most potent greenhouse gases, is used in radiation oncology as a dielectric in linear accelerator waveguides. Given the high global warming potential of SF<sub>6</sub>, its use is heavily regulated, and possible leaks should be proactively monitored. Truebeam Linac diagnostic log files record SF<sub>6</sub> pressure metrics every 2 h. These log files were parsed, and the high time resolution pressure data were studied across a fleet of 15 Varian Truebeam Linear Accelerators for a 1 year period. Average SF<sub>6</sub> leak rates were low, but highly variable (8.6 g/year/Linac, std dev 17.7 g). Pressure fluctuation due to temperature change was found to be a similar magnitude to real SF<sub>6</sub> losses over months. Leak rates calculated from pressure loss were significantly below those reported in the literature and manufacturer specifications. Pressure fluctuation proportional to temperature change caused by Linac use makes SF<sub>6</sub> pressure an unreliable metric to sample infrequently if the aim is to detect small leaks. A novel method for calculating leak rate using high sample rate log files mitigates this effect, giving a more accurate measurement.

Journal of Medical Imaging and Radiation Oncology
Peter MacCallum Cancer Centre (AU)
Openalex Percentile: Top 66%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.