Computed tomography dose management practices and the adoption of automated dose monitoring tools in Australia: a national survey

This study investigates computed tomography (CT) dose management and automatic dose monitoring software (DMS) use in Australian radiology departments. An online survey covering departmental characteristics, dose management practices, DMS usage, and radiation protection activities was distributed through national radiation organisations and social media. Of the 132 initial responses received, 45 were eligible, completed, and analysed. The findings indicate 91% (n = 41/45) of departments regularly assess CT doses, with 63% (n = 26/41) conducting such assessments only once a year. Automatic DMS tools were utilised by 41% (n = 17/41) of these departments for CT dose data collection and analysis, while 59% (n = 24/41) relied on traditional methods. Only 25% (n = 6/24) of non-DMS users indicated plans for future adoption. A radiation protection team was present in 41% (n = 17/41) of departments. While dose assessment is commonly practised, it mostly relies on manual methods and is performed infrequently. Broader DMS implementation and formal radiation protection teams are recommended to strengthen CT dose management and enable continuous monitoring.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-09-23
DOI
https://doi.org/10.1093/rpd/ncaf109
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computed tomography dose management practices and the adoption of automated dose monitoring tools in Australia: a national survey

Peter Kench, Seyedamir Tavakoli Taba‬, Ernest Usang Ekpo, Mohammed Alanazi
1 citations
Radiation Protection Dosimetry
Radiation Dose and Imaging
1.36
article

Computed tomography dose management practices and the adoption of automated dose monitoring tools in Australia: a national survey

Peter Kench, Seyedamir Tavakoli Taba‬, Ernest Usang Ekpo, Mohammed Alanazi
article en
1 citations

Abstract

This study investigates computed tomography (CT) dose management and automatic dose monitoring software (DMS) use in Australian radiology departments. An online survey covering departmental characteristics, dose management practices, DMS usage, and radiation protection activities was distributed through national radiation organisations and social media. Of the 132 initial responses received, 45 were eligible, completed, and analysed. The findings indicate 91% (n = 41/45) of departments regularly assess CT doses, with 63% (n = 26/41) conducting such assessments only once a year. Automatic DMS tools were utilised by 41% (n = 17/41) of these departments for CT dose data collection and analysis, while 59% (n = 24/41) relied on traditional methods. Only 25% (n = 6/24) of non-DMS users indicated plans for future adoption. A radiation protection team was present in 41% (n = 17/41) of departments. While dose assessment is commonly practised, it mostly relies on manual methods and is performed infrequently. Broader DMS implementation and formal radiation protection teams are recommended to strengthen CT dose management and enable continuous monitoring.

Radiation Protection DosimetryVol. 201(17)
The University of Sydney (AU), Majmaah University (SA)
NSW Agency for Clinical Innovation
Openalex Percentile: Top 16%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.