Performance Analysis of Over Current Relay on 20 kV Distribution Network Feeders Using MATLAB

Short circuit disturbances in electrical distribution systems can cause severe damage to equipment and compromise system stability if not properly addressed. To mitigate these impacts and maintain system reliability, protection devices such as overcurrent relays (OCR) are widely used to detect and automatically isolate overcurrent conditions. This study aims to analyze the magnitude of short circuit current and evaluate the performance of OCR in responding to faults in a 20 kV medium-voltage distribution network. The analysis was conducted using MATLAB Simulink, modeling the distribution system with parameters adjusted to actual system conditions. The simulation was carried out under two scenarios: normal operating conditions to ensure the OCR remains inactive when the current is within safe limits, and fault conditions to evaluate the accuracy and speed of the OCR response to overcurrent events. Simulation results show that the magnitude of the short circuit current decreases with the distance from the source, with values of 5,565.92 A at 5% of the feeder length, 1,367.25 A at 25%, 698.52 A at 50%, 468.87 A at 75%, and 352.83 A at 100%. Under normal conditions, the current waveform remains stable throughout the 0.2-second simulation period. In contrast, under fault conditions, a current surge exceeding the threshold occurs at 0.1 seconds, triggering the OCR. The relay responds promptly and accurately in accordance with the designed inverse-time characteristics, demonstrating its effectiveness and reliability in detecting and clearing short circuit faults in 20 kV distribution networks.

Authors

Institutions

Publication Details

Journal
Journal of Power, Energy, and Control
Published
2025-09-22
DOI
https://doi.org/10.62777/pec.v2i2.57
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of Over Current Relay on 20 kV Distribution Network Feeders Using MATLAB

Muhammad Daud, Raihan Putri, Arnawan Hasibuan
Journal of Power, Energy, and Control
Power Systems Fault Detection
article

Performance Analysis of Over Current Relay on 20 kV Distribution Network Feeders Using MATLAB

Muhammad Daud, Raihan Putri, Arnawan Hasibuan
article en

Abstract

Short circuit disturbances in electrical distribution systems can cause severe damage to equipment and compromise system stability if not properly addressed. To mitigate these impacts and maintain system reliability, protection devices such as overcurrent relays (OCR) are widely used to detect and automatically isolate overcurrent conditions. This study aims to analyze the magnitude of short circuit current and evaluate the performance of OCR in responding to faults in a 20 kV medium-voltage distribution network. The analysis was conducted using MATLAB Simulink, modeling the distribution system with parameters adjusted to actual system conditions. The simulation was carried out under two scenarios: normal operating conditions to ensure the OCR remains inactive when the current is within safe limits, and fault conditions to evaluate the accuracy and speed of the OCR response to overcurrent events. Simulation results show that the magnitude of the short circuit current decreases with the distance from the source, with values of 5,565.92 A at 5% of the feeder length, 1,367.25 A at 25%, 698.52 A at 50%, 468.87 A at 75%, and 352.83 A at 100%. Under normal conditions, the current waveform remains stable throughout the 0.2-second simulation period. In contrast, under fault conditions, a current surge exceeding the threshold occurs at 0.1 seconds, triggering the OCR. The relay responds promptly and accurately in accordance with the designed inverse-time characteristics, demonstrating its effectiveness and reliability in detecting and clearing short circuit faults in 20 kV distribution networks.

Journal of Power, Energy, and ControlVol. 2(2)
Malikussaleh University (ID)
Openalex Percentile: Top 68%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.