Development of a methodology for the application of vinyl paint as a radon mitigation barrier for interior spaces

Radon gas is a radioactive gas produced by the decay of uranium and radium, which occur naturally in soil and rock. Radon gas can migrate into buildings from the ground and, to a lesser extent, from building materials such as bricks, granite and concrete. The accumulation of radon indoors can pose a significant health risk, as its inhalation can damage lung tissue, making it the second leading cause of lung cancer after smoking. In 2013, the European Union adopted Directive 2013/59/EURATOM, establishing an average reference level of 300 Bq/m 3 in inhabited areas and the obligation to measure building radon concentrations. In Spain, Royal Decree 732/2019 adapts this directive and establishes specific requirements to protect people from radon exposure. The main mitigation measures include sealing cracks, natural or forced ventilation, sub-slab depressurisation and installing radon barriers. Although current measures are effective, research continues into new solutions to further reduce indoor radon levels. This work focuses on developing an evaluating a methodology for applying a commercially available regular indoor paint to ensure that it can be used as an anti-radon barrier in walls. The results show that a vinyl paint can be used to mitigate radon in indoor spaces reaching a radon concentration reduction percentage of 82.25%, and a diffusion coefficient of 7.48·10 -11 m 2 /s. The increase in the number of coats is proportional to the effectiveness for radon reduction per unit thickness, with the best results achieved at thicknesses of 90 microns. These results open the possibility of using decorative surface coatings to mitigate the access of radon gas indoors in a simple, accessible and low-cost way that contributes to improving indoor air quality and reducing the impact of radon gas on people's health. • Vinyl paint can be used to mitigate radon in interior spaces. • It is a simple and low-cost mitigation technique to reduce indoor radon. • Its application requires at least 4 coats of paint to achieve 82.25% radon mitigation. • Radon diffusion coefficient of about 10 -11 m 2 /s is obtained for all paint coats. • Mitigation efficacy increases with coat number, being effective from 4 layers.

Authors

Institutions

Publication Details

Journal
Radiation Physics and Chemistry
Published
2025-09-23
DOI
https://doi.org/10.1016/j.radphyschem.2025.113334
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a methodology for the application of vinyl paint as a radon mitigation barrier for interior spaces

G. Verdú, Beatriz Ruvira, Salvador Cardona, J.M. Arnal et al.
Radiation Physics and Chemistry
Radioactivity and Radon Measurements
article

Development of a methodology for the application of vinyl paint as a radon mitigation barrier for interior spaces

G. Verdú, Beatriz Ruvira, Salvador Cardona, J.M. Arnal, B. García-Fayos, B. García-Gimeno
article en

Abstract

Radon gas is a radioactive gas produced by the decay of uranium and radium, which occur naturally in soil and rock. Radon gas can migrate into buildings from the ground and, to a lesser extent, from building materials such as bricks, granite and concrete. The accumulation of radon indoors can pose a significant health risk, as its inhalation can damage lung tissue, making it the second leading cause of lung cancer after smoking. In 2013, the European Union adopted Directive 2013/59/EURATOM, establishing an average reference level of 300 Bq/m 3 in inhabited areas and the obligation to measure building radon concentrations. In Spain, Royal Decree 732/2019 adapts this directive and establishes specific requirements to protect people from radon exposure. The main mitigation measures include sealing cracks, natural or forced ventilation, sub-slab depressurisation and installing radon barriers. Although current measures are effective, research continues into new solutions to further reduce indoor radon levels. This work focuses on developing an evaluating a methodology for applying a commercially available regular indoor paint to ensure that it can be used as an anti-radon barrier in walls. The results show that a vinyl paint can be used to mitigate radon in indoor spaces reaching a radon concentration reduction percentage of 82.25%, and a diffusion coefficient of 7.48·10 -11 m 2 /s. The increase in the number of coats is proportional to the effectiveness for radon reduction per unit thickness, with the best results achieved at thicknesses of 90 microns. These results open the possibility of using decorative surface coatings to mitigate the access of radon gas indoors in a simple, accessible and low-cost way that contributes to improving indoor air quality and reducing the impact of radon gas on people's health. • Vinyl paint can be used to mitigate radon in interior spaces. • It is a simple and low-cost mitigation technique to reduce indoor radon. • Its application requires at least 4 coats of paint to achieve 82.25% radon mitigation. • Radon diffusion coefficient of about 10 -11 m 2 /s is obtained for all paint coats. • Mitigation efficacy increases with coat number, being effective from 4 layers.

Radiation Physics and ChemistryVol. 239
Universitat Politècnica de València (ES)
Openalex Percentile: Top 63%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.