Structural and thermal performance of masonry walls: Insights from TRM-based upgrading techniques

Masonry buildings, often constructed without adherence to modern seismic standards, are highly vulnerable to seismic events. Retrofitting techniques, such as Textile Reinforced Mortar (TRM), offer effective solutions for enhancing both structural and thermal performance. This study investigates the retrofitting of hollow clay-brick and concrete-brick masonry walls using TRM systems composed of various textile combinations, including galvanized steel and glass fiber textiles, as well as basalt fiber with Inox steel micro-fiber textiles, along with configurations of four or five diatons. Structural performance was evaluated through in-plane cyclic tests, demonstrating a significant increase in load-bearing capacity: approximately 90 % for clay-brick walls and 23 % for concrete-brick walls. To address energy efficiency, the TRM-upgraded/retrofitted walls were thermally upgraded with lime-based insulating mortar (mixed with recycled aggregates) and assessed in a climate chamber. Results revealed a substantial reduction in thermal transmittance for upgraded/retrofitted clay-brick and upgraded/retrofitted concrete-brick walls, and drops of about 44 % and 34 %, respectively, were observed compared to un-strengthened samples. Notably, the recycled aggregates are responsible for improving the insulation property of the masonry wall. Overall, the integrated TRM retrofitting approach effectively enhances both the seismic resilience and thermal efficiency of masonry structures. • TRM systems enhance seismic and thermal performance of masonry walls. • Clay-brick walls showed up to 90 % load-bearing capacity improvement with TRM. • Thermal transmittance decreased by 44 % with lime-based insulating mortars. • Basalt and galvanized steel textiles provided effective reinforcement. • TRM retrofitting offers sustainable solutions for masonry upgrading.

Authors

Institutions

Publication Details

Journal
Structures
Published
2025-09-23
DOI
https://doi.org/10.1016/j.istruc.2025.110200
Citations
2
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural and thermal performance of masonry walls: Insights from TRM-based upgrading techniques

Andrea Frattolillo, Flavio Stochino, Mauro Sassu, Mónica Valdés et al.
2 citations
Structures
Masonry and Concrete Structural Analysis
1.91
article

Structural and thermal performance of masonry walls: Insights from TRM-based upgrading techniques

Andrea Frattolillo, Flavio Stochino, Mauro Sassu, Mónica Valdés, Fausto Mistretta, Arnas Majumder
article en
2 citations

Abstract

Masonry buildings, often constructed without adherence to modern seismic standards, are highly vulnerable to seismic events. Retrofitting techniques, such as Textile Reinforced Mortar (TRM), offer effective solutions for enhancing both structural and thermal performance. This study investigates the retrofitting of hollow clay-brick and concrete-brick masonry walls using TRM systems composed of various textile combinations, including galvanized steel and glass fiber textiles, as well as basalt fiber with Inox steel micro-fiber textiles, along with configurations of four or five diatons. Structural performance was evaluated through in-plane cyclic tests, demonstrating a significant increase in load-bearing capacity: approximately 90 % for clay-brick walls and 23 % for concrete-brick walls. To address energy efficiency, the TRM-upgraded/retrofitted walls were thermally upgraded with lime-based insulating mortar (mixed with recycled aggregates) and assessed in a climate chamber. Results revealed a substantial reduction in thermal transmittance for upgraded/retrofitted clay-brick and upgraded/retrofitted concrete-brick walls, and drops of about 44 % and 34 %, respectively, were observed compared to un-strengthened samples. Notably, the recycled aggregates are responsible for improving the insulation property of the masonry wall. Overall, the integrated TRM retrofitting approach effectively enhances both the seismic resilience and thermal efficiency of masonry structures. • TRM systems enhance seismic and thermal performance of masonry walls. • Clay-brick walls showed up to 90 % load-bearing capacity improvement with TRM. • Thermal transmittance decreased by 44 % with lime-based insulating mortars. • Basalt and galvanized steel textiles provided effective reinforcement. • TRM retrofitting offers sustainable solutions for masonry upgrading.

StructuresVol. 81
University of Cagliari (IT)
Openalex Percentile: Top 13%
Masonry and Concrete Structural Analysis
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.