Development and tracking of inferior vena cava diameter after filter placement using a circle-fitting predictive model

The diameter of the inferior vena cava (IVC) is a critical factor in the decision-making process for IVC filter (IVCF) placement. A mismatched filter can compromise its stability and potentially lead to adverse events. This study develops and validates a predictive model using a circle-fitting algorithm to estimate the IVC diameter after filter placement. The findings suggest that single-angle measurements may misrepresent the filter-vessel compatibility, since the IVC transforms from an oval to a near-circular cross-section following filter placement. The predictive model, integrating three-dimensional, multi-angle cavography with circumference-based calculations, demonstrates excellent concordance with both post-placement maximum and minimum diameters in animal and clinical samples. Compared to the conventional single-angle measurements prior to IVCF placement, the predictive diameter can provide a more accurate and reliable representation of the IVC size, which was superior to either the maximum or minimum diameter alone, suggesting a higher predictive reliability. This model may provide a valuable tool for more accurate IVCF diameter selection and support future research.

Authors

Institutions

Publication Details

Journal
iScience
Published
2025-09-23
DOI
https://doi.org/10.1016/j.isci.2025.113616
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and tracking of inferior vena cava diameter after filter placement using a circle-fitting predictive model

Maofeng Gong, Jianping Gu, Xu He, Rui Jiang
iScience
Venous Thromboembolism Diagnosis and Management
article

Development and tracking of inferior vena cava diameter after filter placement using a circle-fitting predictive model

Maofeng Gong, Jianping Gu, Xu He, Rui Jiang
article en

Abstract

The diameter of the inferior vena cava (IVC) is a critical factor in the decision-making process for IVC filter (IVCF) placement. A mismatched filter can compromise its stability and potentially lead to adverse events. This study develops and validates a predictive model using a circle-fitting algorithm to estimate the IVC diameter after filter placement. The findings suggest that single-angle measurements may misrepresent the filter-vessel compatibility, since the IVC transforms from an oval to a near-circular cross-section following filter placement. The predictive model, integrating three-dimensional, multi-angle cavography with circumference-based calculations, demonstrates excellent concordance with both post-placement maximum and minimum diameters in animal and clinical samples. Compared to the conventional single-angle measurements prior to IVCF placement, the predictive diameter can provide a more accurate and reliable representation of the IVC size, which was superior to either the maximum or minimum diameter alone, suggesting a higher predictive reliability. This model may provide a valuable tool for more accurate IVCF diameter selection and support future research.

iScienceVol. 28(10)
Nanjing Medical University (CN)
Openalex Percentile: Top 56%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and tracking of inferior vena cava diameter after filter placement using a circle-fitting predictive model — Maofeng Gong, Jianping Gu, et al. · iScience (2025) | TGRS Research Map | TGRS