SEM/EDS and Roughness Analysis on Current Titanium Implant Decontamination Systems: In Vitro Study

The aim of this study was to evaluate the effects of different decontamination treatments on the surface roughness and elemental deposition of pristine dental implants using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). We divided 110 dental implants into 21 groups based on the decontamination method used in vitro. One group was the untreated control. Roughness values (Ra) were analyzed with a profilometer, while elemental deposition was assessed through EDS. Results were obtained for each treatment and for macrogroups (control, ultrasound, curettes, powders, brushes, gels). Significantly lower Ra values were found in the neck zone with respect to the thread zone (p < 0.05). EDS analysis revealed a non-significant higher presence of carbon and calcium in certain treatments, denoting a certain deposition of the decontaminating products (p > 0.05). Although there were various significant differences among the groups, roughness values were low and no decontaminating methods macroscopically affected implant surfaces, so decontaminating procedures can be considered safe.

Authors

Institutions

Publication Details

Journal
Coatings
Published
2025-09-23
DOI
https://doi.org/10.3390/coatings15101114
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SEM/EDS and Roughness Analysis on Current Titanium Implant Decontamination Systems: In Vitro Study

Andrea Scribante, Maurizio Pascadopoli, Mario Alovisi, Marco Lattari et al.
Coatings
Dental Implant Techniques and Outcomes
article

SEM/EDS and Roughness Analysis on Current Titanium Implant Decontamination Systems: In Vitro Study

Andrea Scribante, Maurizio Pascadopoli, Mario Alovisi, Marco Lattari, Andrea Butera, Saverio Cosola, Simone Roatti, Beatrice Alberti
article en

Abstract

The aim of this study was to evaluate the effects of different decontamination treatments on the surface roughness and elemental deposition of pristine dental implants using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). We divided 110 dental implants into 21 groups based on the decontamination method used in vitro. One group was the untreated control. Roughness values (Ra) were analyzed with a profilometer, while elemental deposition was assessed through EDS. Results were obtained for each treatment and for macrogroups (control, ultrasound, curettes, powders, brushes, gels). Significantly lower Ra values were found in the neck zone with respect to the thread zone (p < 0.05). EDS analysis revealed a non-significant higher presence of carbon and calcium in certain treatments, denoting a certain deposition of the decontaminating products (p > 0.05). Although there were various significant differences among the groups, roughness values were low and no decontaminating methods macroscopically affected implant surfaces, so decontaminating procedures can be considered safe.

CoatingsVol. 15(10)
University of Sassari (IT), University of Pavia (IT), University of Turin (IT)
Openalex Percentile: Top 64%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.