Alternative Methodology for Cortisol Evaluation Before and After Sheep Shearing Using Raman Spectroscopy: A Feasibility Study

This research proposed a feasibility study for a qualitative and semiquantitative analysis of sheep serum using Raman Spectroscopy analysis as an alternative to standard methodologies. Raman Spectroscopy was used to obtain information about molecular vibrations that can provide information about the behavior of specific variations in the protein network. This study was conducted during the traditional vernal shearing procedure in Sicilian sheep breeding. Twenty female sheep were randomly chosen from a one-hundred Comisana-bred flock habituated to the handling required for shearing and venipuncture. Animals had a mean body weight of 52.35 ± 4.55 kg, were aged between 2 and 3 years old, and were clinically healthy with no evidence of disease and free from internal and external parasites. All animals were shorn on the same day by hand using traditional shearing scissors in a 15 m × 10 m pen. The animals were released into an adjacent pen at the end of the shearing procedure. For each animal, blood samples were collected through jugular venipuncture into a vacutainer tube with a clot activator (Terumo Corporation, Japan) immediately before and 5 and 60 min after the end of the shearing procedure. On the obtained sera, ELISA and Raman spectroscopy analyses were performed to evaluate cortisol concentrations. The band area corresponding to the cortisol vibration mode was identified in the 1300-1366 cm<sup>-1</sup> band. The Raman spectra obtained during the various protocol data points showed the same trend, with differences in the intensity of the band area 1300-1366 cm<sup>-1</sup>. A positive correlation was found between ELISA and Raman assessment in all experimental conditions. The obtained results demonstrate that Raman spectroscopy analysis could be a suitable tool for biomolecule identification. This study demonstrated that this technique provides useful information for understanding sheep responses to stress induced by management conditions.

Authors

Institutions

Publication Details

Journal
Animals
Published
2025-09-23
DOI
https://doi.org/10.3390/ani15192776
Primary Topic
Meat and Animal Product Quality
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Alternative Methodology for Cortisol Evaluation Before and After Sheep Shearing Using Raman Spectroscopy: A Feasibility Study

Claudia Giannetto, Francesca Arfuso, Maria Antonietta Rizzo, Alessandro Attanzio et al.
Animals
Meat and Animal Product Quality
article

Alternative Methodology for Cortisol Evaluation Before and After Sheep Shearing Using Raman Spectroscopy: A Feasibility Study

Claudia Giannetto, Francesca Arfuso, Maria Antonietta Rizzo, Alessandro Attanzio, Giuseppe Acri, Giuseppe Piccione, Alberto Scoglio, Barbara Testagrossa
article en

Abstract

This research proposed a feasibility study for a qualitative and semiquantitative analysis of sheep serum using Raman Spectroscopy analysis as an alternative to standard methodologies. Raman Spectroscopy was used to obtain information about molecular vibrations that can provide information about the behavior of specific variations in the protein network. This study was conducted during the traditional vernal shearing procedure in Sicilian sheep breeding. Twenty female sheep were randomly chosen from a one-hundred Comisana-bred flock habituated to the handling required for shearing and venipuncture. Animals had a mean body weight of 52.35 ± 4.55 kg, were aged between 2 and 3 years old, and were clinically healthy with no evidence of disease and free from internal and external parasites. All animals were shorn on the same day by hand using traditional shearing scissors in a 15 m × 10 m pen. The animals were released into an adjacent pen at the end of the shearing procedure. For each animal, blood samples were collected through jugular venipuncture into a vacutainer tube with a clot activator (Terumo Corporation, Japan) immediately before and 5 and 60 min after the end of the shearing procedure. On the obtained sera, ELISA and Raman spectroscopy analyses were performed to evaluate cortisol concentrations. The band area corresponding to the cortisol vibration mode was identified in the 1300-1366 cm<sup>-1</sup> band. The Raman spectra obtained during the various protocol data points showed the same trend, with differences in the intensity of the band area 1300-1366 cm<sup>-1</sup>. A positive correlation was found between ELISA and Raman assessment in all experimental conditions. The obtained results demonstrate that Raman spectroscopy analysis could be a suitable tool for biomolecule identification. This study demonstrated that this technique provides useful information for understanding sheep responses to stress induced by management conditions.

AnimalsVol. 15(19)
University of Messina (IT), University of Palermo (IT)
Openalex Percentile: Top 71%
Meat and Animal Product Quality
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.