Data Analysis of Smart Electricity Meters under Unbalanced Current Conditions

During the operation of the electric energy metering device, in addition to the common faults such as the loss of voltage in the secondary circuit of the voltage transformer, there are also faults such as the disconnection of the secondary circuit of the current transformer, which will lead to inaccurate metering and affect the safety of personnel and equipment. In this paper, combined with the 10kV special transformer user, during the operation of the electric energy metering device, the current loop of the test junction box is poorly contacted, and according to the change law of the curve data of the acquisition system, the correction coefficient method is used to calculate the amount of rebate and compensation, and detailed measures are proposed to effectively prevent the fault of the secondary circuit of the current transformer.

Authors

Institutions

Publication Details

Published
2025-08-08
DOI
https://doi.org/10.1109/iaeac65194.2025.11166491
Primary Topic
Electricity Theft Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data Analysis of Smart Electricity Meters under Unbalanced Current Conditions

Di Wu, Shiliang Chang, Haiwen Wu, Xing Huang et al.
Electricity Theft Detection Techniques
article

Data Analysis of Smart Electricity Meters under Unbalanced Current Conditions

Di Wu, Shiliang Chang, Haiwen Wu, Xing Huang, Xuesong Wang, Jun Duan, Changkai Yu
article en

Abstract

During the operation of the electric energy metering device, in addition to the common faults such as the loss of voltage in the secondary circuit of the voltage transformer, there are also faults such as the disconnection of the secondary circuit of the current transformer, which will lead to inaccurate metering and affect the safety of personnel and equipment. In this paper, combined with the 10kV special transformer user, during the operation of the electric energy metering device, the current loop of the test junction box is poorly contacted, and according to the change law of the curve data of the acquisition system, the correction coefficient method is used to calculate the amount of rebate and compensation, and detailed measures are proposed to effectively prevent the fault of the secondary circuit of the current transformer.

State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Openalex Percentile: Top 74%
Electricity Theft Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.