Impact of Wireless Interferences on ECG Signal Quality in Wearable Cardiac Monitoring Devices

Wireless interference in wearable ECG devices is a significant concern, as it can lead to inaccurate interpretations of cardiac signals in continuous monitoring applications. The objective is to experimentally investigate the impact of wireless interferences, such as Bluetooth and WiFi, on transmitting ECG signals in normal and diseased states. ECG signals generated using a hardware simulator are transmitted through a Bluetoothbased wireless channel and recorded in an electromagnetically shielded environment. The experimental setup comprises ten test cases that introduce wireless interference sources, including Bluetooth and WiFi sources at the receiver end. Time-domain analysis of recorded ECG signals for both normal and diseased states, demonstrated morphological distortions in recorded ECG amplitude and latency. Further, signal degradation is quantified using the Signal-to-Noise Ratio (SNR) and the results indicate that diseased states exhibit lower SNR compared to the normal state. This reduction occurs due to the non-linear and irregular morphological variations in diseased ECG signals, including phase shifts and amplitude fluctuations, which overlap with external wireless interferences, increasing their susceptibility to signal degradation. FFT-based spectral analysis is performed, to analyze frequency-specific distortions for normal and diseased states. The significant variations in peak magnitude with broader spectral distortions within the 0 to 50 Hz range are observed, particularly for test cases with multiple WiFi interference sources of high transmission power. These findings emphasize the impact of wireless interference on ECG signal quality, underscoring the significance of accurate disease identification in continuous cardiac monitoring systems.

Authors

Institutions

Publication Details

Published
2025-06-05
DOI
https://doi.org/10.1109/wams64402.2025.11158571
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Wireless Interferences on ECG Signal Quality in Wearable Cardiac Monitoring Devices

R. Karunanithi, Rohini Palanisamy, Pandiyarasan Veluswamy
Wireless Body Area Networks
article

Impact of Wireless Interferences on ECG Signal Quality in Wearable Cardiac Monitoring Devices

R. Karunanithi, Rohini Palanisamy, Pandiyarasan Veluswamy
article en

Abstract

Wireless interference in wearable ECG devices is a significant concern, as it can lead to inaccurate interpretations of cardiac signals in continuous monitoring applications. The objective is to experimentally investigate the impact of wireless interferences, such as Bluetooth and WiFi, on transmitting ECG signals in normal and diseased states. ECG signals generated using a hardware simulator are transmitted through a Bluetoothbased wireless channel and recorded in an electromagnetically shielded environment. The experimental setup comprises ten test cases that introduce wireless interference sources, including Bluetooth and WiFi sources at the receiver end. Time-domain analysis of recorded ECG signals for both normal and diseased states, demonstrated morphological distortions in recorded ECG amplitude and latency. Further, signal degradation is quantified using the Signal-to-Noise Ratio (SNR) and the results indicate that diseased states exhibit lower SNR compared to the normal state. This reduction occurs due to the non-linear and irregular morphological variations in diseased ECG signals, including phase shifts and amplitude fluctuations, which overlap with external wireless interferences, increasing their susceptibility to signal degradation. FFT-based spectral analysis is performed, to analyze frequency-specific distortions for normal and diseased states. The significant variations in peak magnitude with broader spectral distortions within the 0 to 50 Hz range are observed, particularly for test cases with multiple WiFi interference sources of high transmission power. These findings emphasize the impact of wireless interference on ECG signal quality, underscoring the significance of accurate disease identification in continuous cardiac monitoring systems.

Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram (IN)
Openalex Percentile: Top 75%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Wireless Interferences on ECG Signal Quality in Wearable Cardiac Monitoring Devices — R. Karunanithi, Rohini Palanisamy, et al. · (2025) | TGRS Research Map | TGRS