Research on Comparison of Cable Screening Performance Measurement Methods
This paper systematically examines six common measurement techniques for assessing cable screening performance. The advantages, disadvantages, and applicability of each method are compared from both theoretical and experimental perspectives, providing practical references for engineering measurements. The results reveal that the triaxial method offers high measurement accuracy, reliable data, and the ability to simultaneously measure transfer impedance and screening attenuation, making it superior to other methods in practical applications.
Authors
- Xiangming Zhou (ORCID: https://orcid.org/0000-0001-7977-0718)
- Shiping Tang (ORCID: https://orcid.org/0000-0001-5774-587X)
- Zhicheng Xue
- Guangxin Ji
Institutions
- Southeast University (BD)
- Southeast University (CN)
Publication Details
- Published
- 2025-08-08
- DOI
- https://doi.org/10.1109/iaeac65194.2025.11165926
- Primary Topic
- Elevator Systems and Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00