Analysis of Causes of Abnormal Electricity Consumption in Reverse Phase Sequence Voltage Conditions of Smart Electric Meters

In addition to common faults such as loss of current in the secondary circuit of current transformers and loss of voltage in the secondary circuit of voltage transformers, there are also faults such as phase errors in voltage and current of smart electric meters, and reverse polarity connections of voltage transformers and current transformers during the operation of electrical energy metering devices. These faults lead to inaccurate metering, affecting the fairness and impartiality of metering. This paper combines the complex metering faults of reverse phase sequence voltage and reverse polarity connection of current encountered during the operation of 10kV high-voltage supply and high-voltage metering users. Based on the variation patterns of data curves from the acquisition system and the steps for live wiring inspection, the paper introduces methods for analyzing and judging metering faults, drawing conclusions on incorrect wiring. By considering the nature of the load and the average power factor angle, two methods, namely the correction coefficient method and the error rate method, are used to calculate the compensation for electricity. Measures are proposed for prevention.

Authors

Institutions

Publication Details

Published
2025-08-08
DOI
https://doi.org/10.1109/iaeac65194.2025.11166043
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Causes of Abnormal Electricity Consumption in Reverse Phase Sequence Voltage Conditions of Smart Electric Meters

Mingzhong Zeng, Shuwei Wan, Di Wu, Shiliang Chang et al.
Electric Power Systems and Control
article

Analysis of Causes of Abnormal Electricity Consumption in Reverse Phase Sequence Voltage Conditions of Smart Electric Meters

Mingzhong Zeng, Shuwei Wan, Di Wu, Shiliang Chang, Qing He, Changkai Yu, Jianming Hu
article en

Abstract

In addition to common faults such as loss of current in the secondary circuit of current transformers and loss of voltage in the secondary circuit of voltage transformers, there are also faults such as phase errors in voltage and current of smart electric meters, and reverse polarity connections of voltage transformers and current transformers during the operation of electrical energy metering devices. These faults lead to inaccurate metering, affecting the fairness and impartiality of metering. This paper combines the complex metering faults of reverse phase sequence voltage and reverse polarity connection of current encountered during the operation of 10kV high-voltage supply and high-voltage metering users. Based on the variation patterns of data curves from the acquisition system and the steps for live wiring inspection, the paper introduces methods for analyzing and judging metering faults, drawing conclusions on incorrect wiring. By considering the nature of the load and the average power factor angle, two methods, namely the correction coefficient method and the error rate method, are used to calculate the compensation for electricity. Measures are proposed for prevention.

State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Openalex Percentile: Top 74%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.