A Reference-Giving Device Prototype for Performance Assessment of Closed-Loop Robot Systems

Industrial robot systems that determine or adapt their motion at runtime using sensor data are expected to gain popularity in manufacturing, due to higher flexibility, less programming effort and the possibility to enable new processes that have been difficult to automate with classical open-loop motion. For the performance assessment of such robot systems, a new benchmarking method for closed-loop systems, inspired by ISO 9283, was proposed in [1]. However, for real-world experiments, a device is required that allows to shape the measurements recorded by external sensors, and thus creates well-defined (artificial) robot motion. In this paper, we propose a design for such a reference-giving device, show the build and test it for fulfillment of its requirements. Finally, we demonstrate the suitability of the reference-giving device in a closed-loop benchmark on two different state-of-the-art industrial robot systems using the performance assessment methodology from [1].

Authors

Institutions

Publication Details

Published
2025-08-17
DOI
https://doi.org/10.1109/case58245.2025.11163820
Primary Topic
Real-time simulation and control systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Reference-Giving Device Prototype for Performance Assessment of Closed-Loop Robot Systems

Johannes T. Stoll, Alexander Verl, Werner Kraus, Markus Giftthaler et al.
Real-time simulation and control systems
article

A Reference-Giving Device Prototype for Performance Assessment of Closed-Loop Robot Systems

Johannes T. Stoll, Alexander Verl, Werner Kraus, Markus Giftthaler, Christian M. Lehnertz, Martin S. Finkbeiner, Maria Vrhar
article en

Abstract

Industrial robot systems that determine or adapt their motion at runtime using sensor data are expected to gain popularity in manufacturing, due to higher flexibility, less programming effort and the possibility to enable new processes that have been difficult to automate with classical open-loop motion. For the performance assessment of such robot systems, a new benchmarking method for closed-loop systems, inspired by ISO 9283, was proposed in [1]. However, for real-world experiments, a device is required that allows to shape the measurements recorded by external sensors, and thus creates well-defined (artificial) robot motion. In this paper, we propose a design for such a reference-giving device, show the build and test it for fulfillment of its requirements. Finally, we demonstrate the suitability of the reference-giving device in a closed-loop benchmark on two different state-of-the-art industrial robot systems using the performance assessment methodology from [1].

University of Stuttgart (DE), Fraunhofer Institute for Manufacturing Engineering and Automation (DE), Stuttgart Technical University of Applied Sciences (DE), Intrinsic LifeSciences (United States) (US)
Openalex Percentile: Top 68%
Real-time simulation and control systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.