Radiation exposure of chest and abdomen computed tomography in pediatric trauma patients

Combined chest and abdomen computed tomography (CT) in paediatric trauma patients is rare and typically reserved for severely injured patients due to concerns about the potential radiation risks associated with CT in children. This study aims to analyse the radiation exposure of chest and abdomen CT in paediatric patients following trauma resuscitation. A retrospective single-centre study was conducted on patients aged 0-<15 years who underwent CT in the trauma resuscitation unit between 04/2020 and 08/2023. Patients were categorised into three age groups (AGs) (I: 0-<5years, II: 5-<10 years, III: 10-<15 years) and radiation exposure parameters were analysed age-stratified. Effective dose (ED) was calculated using conversion factors and organ doses were determined through Monte Carlo simulations. Out of 212 paediatric patients, 62.7% (133/212) received a CT scan, with 60.2% (80/133) undergoing combined chest and abdomen CT. In 70.0% (56/80), the standard protocol was applied, complete dose data available, and these were included in the dose calculation (median age: 6.2 years; IQR: 3.9-10.5 years; 37.5% female). Radiation exposure was as follows (median [IQR] CTDIvol, DLP, ED): chest: I: 0.7 mGy (0.5-0.8), 13 mGycm (10-16), 2.1 mSv (1.6-2.4); II: 1.4 mGy (1.1-1.9), 35 mGycm (25-49), 3.7 mSv (2.7-5.2); III: 2.7 mGy (2.2-3.2), 76 mGycm (66-95), 4.3 mSv (3.7-5.3); abdomen: I: 0.8 mGy (0.6-0.9), 24 mGycm (20-29), 2.0 mSv (1.6-2.5); II: 1.6 mGy (1.1-1.9), 60 mGycm (41-77), 3.2 mSv (2.2-4.2); III: 3.1 mGy (2.4-3.9), 143 mGycm (101-179), 4.3 mSv (3.0-5.4). In the organ dose analysis, the genital organs were particularly affected by increased radiation exposure. 16.1% (9/56) of patients were not scanned using age-adapted protocols. Chest and abdomen CT in paediatric trauma patients can be performed with moderate radiation exposure. Nonetheless, non-adherence to age-adapted protocols highlights the need for improved compliance to ensure optimal radiation safety in paediatric trauma imaging.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2025-09-23
DOI
https://doi.org/10.1088/1361-6498/ae0a5a
Primary Topic
Abdominal Trauma and Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation exposure of chest and abdomen computed tomography in pediatric trauma patients

Luca Salhöfer, Marcel Opitz, M Drews, Benedikt M. Schaarschmidt et al.
Journal of Radiological Protection
Abdominal Trauma and Injuries
article

Radiation exposure of chest and abdomen computed tomography in pediatric trauma patients

Luca Salhöfer, Marcel Opitz, M Drews, Benedikt M. Schaarschmidt, Johannes Haubold, Marcel Dudda, Bernd Schweiger, Lale Umutlu, Denise Bos, Sebastian Zensen, Michael Forsting, Mathias Meetschen, Raya Serger, Daniel Rosok, Florian Behr, Yannick Laurent Thal
article en

Abstract

Combined chest and abdomen computed tomography (CT) in paediatric trauma patients is rare and typically reserved for severely injured patients due to concerns about the potential radiation risks associated with CT in children. This study aims to analyse the radiation exposure of chest and abdomen CT in paediatric patients following trauma resuscitation. A retrospective single-centre study was conducted on patients aged 0-<15 years who underwent CT in the trauma resuscitation unit between 04/2020 and 08/2023. Patients were categorised into three age groups (AGs) (I: 0-<5years, II: 5-<10 years, III: 10-<15 years) and radiation exposure parameters were analysed age-stratified. Effective dose (ED) was calculated using conversion factors and organ doses were determined through Monte Carlo simulations. Out of 212 paediatric patients, 62.7% (133/212) received a CT scan, with 60.2% (80/133) undergoing combined chest and abdomen CT. In 70.0% (56/80), the standard protocol was applied, complete dose data available, and these were included in the dose calculation (median age: 6.2 years; IQR: 3.9-10.5 years; 37.5% female). Radiation exposure was as follows (median [IQR] CTDIvol, DLP, ED): chest: I: 0.7 mGy (0.5-0.8), 13 mGycm (10-16), 2.1 mSv (1.6-2.4); II: 1.4 mGy (1.1-1.9), 35 mGycm (25-49), 3.7 mSv (2.7-5.2); III: 2.7 mGy (2.2-3.2), 76 mGycm (66-95), 4.3 mSv (3.7-5.3); abdomen: I: 0.8 mGy (0.6-0.9), 24 mGycm (20-29), 2.0 mSv (1.6-2.5); II: 1.6 mGy (1.1-1.9), 60 mGycm (41-77), 3.2 mSv (2.2-4.2); III: 3.1 mGy (2.4-3.9), 143 mGycm (101-179), 4.3 mSv (3.0-5.4). In the organ dose analysis, the genital organs were particularly affected by increased radiation exposure. 16.1% (9/56) of patients were not scanned using age-adapted protocols. Chest and abdomen CT in paediatric trauma patients can be performed with moderate radiation exposure. Nonetheless, non-adherence to age-adapted protocols highlights the need for improved compliance to ensure optimal radiation safety in paediatric trauma imaging.

Journal of Radiological ProtectionVol. 45(4)
University Hospital Bonn (DE), Essen University Hospital (DE), BG Klinikum Duisburg (DE), University of Duisburg-Essen (DE)
Openalex Percentile: Top 59%
Abdominal Trauma and Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.