532/1176 nm all-crystal laser for dual-contrast photoacoustic imaging of blood and lipids

Photoacoustic microscopy (PAM) is a label-free and noninvasive imaging tool for monitoring blood vessels and lipids in vivo. However, simultaneously imaging both indicators has been challenging with a single laser source. Here, we report a compact all-crystal passively Q-switched solid-state laser that simultaneously generates 532 nm and ~1.2 μm wavelengths for blood and lipid contrasts in PAM. The laser leverages both second-harmonic generation (SHG) and stimulated Raman scattering (SRS) in nonlinear crystals. It produces ~2 ns pulses at ~16 kHz repetition rate, satisfying high-performance PAM requirements. We demonstrate dual-wavelength PAM imaging of a USAF1951 test target, blood (hemoglobin), butter, and mouse mesenteric fat. This 532/1176 nm source provides a new, to the best of our knowledge, option for multi-contrast PAM, with potential utility in clinical applications.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-09-23
DOI
https://doi.org/10.1364/ol.573215
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

532/1176 nm all-crystal laser for dual-contrast photoacoustic imaging of blood and lipids

Zechen Li, Yitao Zheng, Hanjie Wang, Zihan Shen et al.
Optics Letters
Photoacoustic and Ultrasonic Imaging
article

532/1176 nm all-crystal laser for dual-contrast photoacoustic imaging of blood and lipids

Zechen Li, Yitao Zheng, Hanjie Wang, Zihan Shen, Jun Dong, Mingyu Li, Lanxin Deng, Hongsen He, Xingyu Zhu
article en

Abstract

Photoacoustic microscopy (PAM) is a label-free and noninvasive imaging tool for monitoring blood vessels and lipids in vivo. However, simultaneously imaging both indicators has been challenging with a single laser source. Here, we report a compact all-crystal passively Q-switched solid-state laser that simultaneously generates 532 nm and ~1.2 μm wavelengths for blood and lipid contrasts in PAM. The laser leverages both second-harmonic generation (SHG) and stimulated Raman scattering (SRS) in nonlinear crystals. It produces ~2 ns pulses at ~16 kHz repetition rate, satisfying high-performance PAM requirements. We demonstrate dual-wavelength PAM imaging of a USAF1951 test target, blood (hemoglobin), butter, and mouse mesenteric fat. This 532/1176 nm source provides a new, to the best of our knowledge, option for multi-contrast PAM, with potential utility in clinical applications.

Optics LettersVol. 50(21)
Xiamen University (CN)
Openalex Percentile: Top 75%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.