Investigation of Tetracycline Removal from Aqueous Environments via Bio-Electro-Fenton Process Using an LDH/CN Cathode

The integration of CuFeMn-Layered Double Hydroxide (LDH) with graphitic carbon nitride (g-C3N4), designated as CFM/CN, was identified as a potential strategy to enhance the photogeneration of hydrogen peroxide (H2O2) and improve the photoelectrocatalytic performance within a Bio-Electro-Fenton (BEF) system. The CFM/CN-BEF system is anticipated to broaden the applicable pH range and augment the overall efficiency of the BEF process, thereby facilitating more effective removal of antibiotics from wastewater. This investigation will systematically evaluate the removal efficiency of tetracycline (TC) as a representative recalcitrant pollutant under a wide range of pH conditions. The findings are expected to provide novel insights into the degradation mechanisms of TC and advance the fundamental understanding of BEF technology for treating refractory organic wastewater.

Authors

Institutions

Publication Details

Journal
Frontiers in Science and Engineering
Published
2025-09-22
DOI
https://doi.org/10.54691/grykrg26
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Tetracycline Removal from Aqueous Environments via Bio-Electro-Fenton Process Using an LDH/CN Cathode

Xiao Liu, Yang Li, J.J. Tong
Frontiers in Science and Engineering
Advanced oxidation water treatment
article

Investigation of Tetracycline Removal from Aqueous Environments via Bio-Electro-Fenton Process Using an LDH/CN Cathode

Xiao Liu, Yang Li, J.J. Tong
article en

Abstract

The integration of CuFeMn-Layered Double Hydroxide (LDH) with graphitic carbon nitride (g-C3N4), designated as CFM/CN, was identified as a potential strategy to enhance the photogeneration of hydrogen peroxide (H2O2) and improve the photoelectrocatalytic performance within a Bio-Electro-Fenton (BEF) system. The CFM/CN-BEF system is anticipated to broaden the applicable pH range and augment the overall efficiency of the BEF process, thereby facilitating more effective removal of antibiotics from wastewater. This investigation will systematically evaluate the removal efficiency of tetracycline (TC) as a representative recalcitrant pollutant under a wide range of pH conditions. The findings are expected to provide novel insights into the degradation mechanisms of TC and advance the fundamental understanding of BEF technology for treating refractory organic wastewater.

Frontiers in Science and EngineeringVol. 5(9)
North China University of Science and Technology (CN)
Openalex Percentile: Top 76%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of Tetracycline Removal from Aqueous Environments via Bio-Electro-Fenton Process Using an LDH/CN Cathode — Xiao Liu, Yang Li, et al. · Frontiers in Science and Engineering (2025) | TGRS Research Map | TGRS