Influence of the Catecholamine Syringe Changeover Method on Patients’ Blood Pressure Variability: A Single-Center Retrospective Study

<b>Background/Objectives</b>: In Japan, evidence on catecholamine syringe exchange methods is limited, with practices varying across facilities and individuals. In this study, we aimed to determine the effect of the catecholamine syringe exchange method on blood pressure variability in intensive care unit patients. <b>Methods</b>: We retrospectively analyzed 119 patients (308 syringe exchanges) who underwent catecholamine syringe exchange between 1 April 2020 and 31 March 2022. Patient characteristics for the double-pumping changeover (DPC) and quick syringe changeover (QC) groups were matched and compared using propensity scores. A sub-analysis focused on patients with severe shock with systolic blood pressures ≤ 90 mmHg. Logistic regression analysis was used to examine factors influencing blood pressure variability during the catecholamine syringe changeover. <b>Results</b>: Neither propensity score matching nor the sub-analysis for patients with shock revealed significant differences in the coefficient of variation or absolute systolic/diastolic/mean blood pressure within 15 min of syringe exchange in the two groups. Logistic regression revealed that age was the sole risk factor affecting blood pressure variability during syringe changeover (odds ratio: 1.018, 95% confidence interval: 1.001-1.036), while syringe changeover methods did not contribute to circulating variability (odds ratio: 1.186, 95% confidence interval: 0.672-2.092). <b>Conclusions</b>: Differences between the DPC and QC methods did not significantly affect blood pressure variability during catecholamine syringe changeovers. However, in older adult patients, catecholamine syringe changeover may be more likely to cause blood pressure variability.

Authors

Institutions

Publication Details

Journal
Nursing Reports
Published
2025-09-23
DOI
https://doi.org/10.3390/nursrep15100345
Primary Topic
Mental Health Research Topics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the Catecholamine Syringe Changeover Method on Patients’ Blood Pressure Variability: A Single-Center Retrospective Study

Kozo Iwasa, Takumi Tsuchida, Ryuta Sato, Y. Niitsu et al.
Nursing Reports
Mental Health Research Topics
article

Influence of the Catecholamine Syringe Changeover Method on Patients’ Blood Pressure Variability: A Single-Center Retrospective Study

Kozo Iwasa, Takumi Tsuchida, Ryuta Sato, Y. Niitsu, Juna Shintaku
article en

Abstract

<b>Background/Objectives</b>: In Japan, evidence on catecholamine syringe exchange methods is limited, with practices varying across facilities and individuals. In this study, we aimed to determine the effect of the catecholamine syringe exchange method on blood pressure variability in intensive care unit patients. <b>Methods</b>: We retrospectively analyzed 119 patients (308 syringe exchanges) who underwent catecholamine syringe exchange between 1 April 2020 and 31 March 2022. Patient characteristics for the double-pumping changeover (DPC) and quick syringe changeover (QC) groups were matched and compared using propensity scores. A sub-analysis focused on patients with severe shock with systolic blood pressures ≤ 90 mmHg. Logistic regression analysis was used to examine factors influencing blood pressure variability during the catecholamine syringe changeover. <b>Results</b>: Neither propensity score matching nor the sub-analysis for patients with shock revealed significant differences in the coefficient of variation or absolute systolic/diastolic/mean blood pressure within 15 min of syringe exchange in the two groups. Logistic regression revealed that age was the sole risk factor affecting blood pressure variability during syringe changeover (odds ratio: 1.018, 95% confidence interval: 1.001-1.036), while syringe changeover methods did not contribute to circulating variability (odds ratio: 1.186, 95% confidence interval: 0.672-2.092). <b>Conclusions</b>: Differences between the DPC and QC methods did not significantly affect blood pressure variability during catecholamine syringe changeovers. However, in older adult patients, catecholamine syringe changeover may be more likely to cause blood pressure variability.

Nursing ReportsVol. 15(10)
Hokkaido University Hospital (JP)
Openalex Percentile: Top 73%
Mental Health Research Topics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.