Evaluating the Energy Efficiency of Green Roof Systems in Residential Buildings: A Case Study in Abuja, Nigeria

This study assesses the impact of green roof systems on electricity consumption in a residential building located in Abuja, Nigeria. Using empirical data from the Abuja Electricity Distribution Company (AEDC) in an existing building for instrument validation and simulation outputs from EnergyPlus via DesignBuilder, the research compares three roof scenarios: conventional, intensive green roof, and extensive green roof. Results reveal that buildings with extensive green roofs consistently exhibit the lowest monthly electricity demand, averaging below 700 kWh, while conventional roofs peak at over 940 kWh. A Pearson correlation coefficient of 1.000 between actual and simulated data confirms the reliability of the simulation model. The findings emphasise the energy-saving potential of green roofs, particularly extensive systems, in hot-humid climates and support their integration into sustainable building design strategies

Authors

Institutions

Publication Details

Journal
Knowledge Web Multidisciplinary International Journal
Published
2025-09-23
DOI
https://doi.org/10.64488/kwmij.v1i2.15
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Energy Efficiency of Green Roof Systems in Residential Buildings: A Case Study in Abuja, Nigeria

Abdullahi, Modi, Ayenajeh, Idakwoji
1 citations
Knowledge Web Multidisciplinary International Journal
Building Energy and Comfort Optimization
1.01
article

Evaluating the Energy Efficiency of Green Roof Systems in Residential Buildings: A Case Study in Abuja, Nigeria

Abdullahi, Modi, Ayenajeh, Idakwoji
article en
1 citations

Abstract

This study assesses the impact of green roof systems on electricity consumption in a residential building located in Abuja, Nigeria. Using empirical data from the Abuja Electricity Distribution Company (AEDC) in an existing building for instrument validation and simulation outputs from EnergyPlus via DesignBuilder, the research compares three roof scenarios: conventional, intensive green roof, and extensive green roof. Results reveal that buildings with extensive green roofs consistently exhibit the lowest monthly electricity demand, averaging below 700 kWh, while conventional roofs peak at over 940 kWh. A Pearson correlation coefficient of 1.000 between actual and simulated data confirms the reliability of the simulation model. The findings emphasise the energy-saving potential of green roofs, particularly extensive systems, in hot-humid climates and support their integration into sustainable building design strategies

Knowledge Web Multidisciplinary International JournalVol. 1(2)
Bingham University (NG)
Openalex Percentile: Top 20%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.