X-ray beam collimation in radiography: a study of compliance among radiographers

To assess collimation practices and quantify the irradiated area outside the area of diagnostic interest (ADI). 1503 radiographs (627 females and 876 males) of seven body regions for patients with (≤ 1-year, 1–12 years, 13–17 years, 18–65 years, ≥ 65-years) age groups from three major hospitals (A. governmental hospital, B. university affiliated hospital, and C. private hospital) in northern Jordan were included. For each radiograph, the length and width of the irradiated area and of the ADI were measured. Then the ratio factors (RF), the irradiated area outside ADI, and the percentage of irradiated area outside ADI were calculated. Kruskal-Wallis and Mann-Whitney-U tests were used to examine the differences in ADI, the irradiated area outside ADI and RF according to age and gender. A regression analysis identified variables associated with RF and irradiated area outside ADI and its percentage. The RF range from 1.7-3.5. Patients aged ≤ 1 year exhibited significantly higher irradiated area outside ADI (722.1 cm 2 ), RF (3.7), and the percentage of irradiated area outside the ADI (72.7%) compared to other age groups ( P <0.001). The actual collimation, area of ADI, and the irradiated area outside the ADI were significantly higher in males than those in females ( P <0.001). Hospital A had a significantly higher irradiated area outside the ADI (871.4 cm 2 ), RF (3.1), and percentage of irradiated area outside the ADI (67.2%) than other hospitals ( P <0.001) which can be due to high patient volume in governmental hospitals and less time to pay attention to patient protection. This study found inadequate X-ray beam collimation practice among radiographers in all participating hospitals, the radiation fields were at least two times larger than the ADI. This raises the importance of educating radiographers on collimation techniques and ensuring that all hospitals adhere to standardized collimation practices.

Authors

Institutions

Publication Details

Journal
Radiation Medicine and Protection
Published
2025-09-23
DOI
https://doi.org/10.1016/j.radmp.2025.09.003
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

X-ray beam collimation in radiography: a study of compliance among radiographers

Maram Alakhras, Dana S. Al‐Mousa, Alaa Oteir, Islam Kleib
Radiation Medicine and Protection
Radiation Dose and Imaging
article

X-ray beam collimation in radiography: a study of compliance among radiographers

Maram Alakhras, Dana S. Al‐Mousa, Alaa Oteir, Islam Kleib
article en

Abstract

To assess collimation practices and quantify the irradiated area outside the area of diagnostic interest (ADI). 1503 radiographs (627 females and 876 males) of seven body regions for patients with (≤ 1-year, 1–12 years, 13–17 years, 18–65 years, ≥ 65-years) age groups from three major hospitals (A. governmental hospital, B. university affiliated hospital, and C. private hospital) in northern Jordan were included. For each radiograph, the length and width of the irradiated area and of the ADI were measured. Then the ratio factors (RF), the irradiated area outside ADI, and the percentage of irradiated area outside ADI were calculated. Kruskal-Wallis and Mann-Whitney-U tests were used to examine the differences in ADI, the irradiated area outside ADI and RF according to age and gender. A regression analysis identified variables associated with RF and irradiated area outside ADI and its percentage. The RF range from 1.7-3.5. Patients aged ≤ 1 year exhibited significantly higher irradiated area outside ADI (722.1 cm 2 ), RF (3.7), and the percentage of irradiated area outside the ADI (72.7%) compared to other age groups ( P <0.001). The actual collimation, area of ADI, and the irradiated area outside the ADI were significantly higher in males than those in females ( P <0.001). Hospital A had a significantly higher irradiated area outside the ADI (871.4 cm 2 ), RF (3.1), and percentage of irradiated area outside the ADI (67.2%) than other hospitals ( P <0.001) which can be due to high patient volume in governmental hospitals and less time to pay attention to patient protection. This study found inadequate X-ray beam collimation practice among radiographers in all participating hospitals, the radiation fields were at least two times larger than the ADI. This raises the importance of educating radiographers on collimation techniques and ensuring that all hospitals adhere to standardized collimation practices.

Radiation Medicine and ProtectionVol. 6(5)
Charles Sturt University (AU), Jordan University of Science and Technology (JO)
Openalex Percentile: Top 62%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.