Assessing dosimetric performance of HyperArc for thyroid-associated ophthalmopathy radiotherapy

To assess the dosimetric performance of HyperArc in comparison with coplanar volumetric modulated arc therapy (c-VMAT) and non-coplanar VMAT (nc-VMAT) in the radiotherapy of thyroid-associated ophthalmopathy (TAO). This retrospective study involved 10 patients with TAO who received radiotherapy at our center from December 2021 to December 2023. A single qualified physicist generated treatment plans using c-VMAT, nc-VMAT, and HyperArc techniques on the TrueBeam machine with the Eclipse treatment planning system. We compared the dosimetric parameters for target volumes and organs at risk (OARs) among these planning approaches. Monitor units (MUs) were also evaluated to assess beam efficiency and delivery effectiveness for each plan type. Compared to c-VMAT and nc-VMAT plans, HyperArc plans achieved the highest conformity index (CI), with increases of 3.35% ( t = 3.84, P = 0.004) and 4.05% ( t = 5.01, P = 0.001), respectively. They also achieved the lowest gradient index (GI), with decreases of 29.41% ( t = -10.41, P < 0.001) and 25.11% ( t = -5.55, P < 0.001), respectively, and the lowest R 50% , with decreases of 31.69% ( t = -11.74, P < 0.001) and 28.01% ( t = -5.50, P < 0.001), respectively. In terms of the dosimetric parameters of OARs, HyperArc plans produced the best results among the three types of plans. Furthermore, HyperArc plans reduced MUs by 31.39% ( t = -8.59, P < 0.001) and 20.60% ( t = -2.70, P = 0.024) compared to c-VMAT and nc-VMAT plans, respectively. This study compared c-VMAT, nc-VMAT, and HyperArc for the radiotherapy of TAO and demonstrated the superior dosimetric performance of HyperArc. HyperArc provided better dose conformity for targets, sharper dose falloff outside targets, more effective sparing of OARs, and more efficient utilization and delivery of rays.

Authors

Institutions

Publication Details

Journal
Radiation Medicine and Protection
Published
2025-09-23
DOI
https://doi.org/10.1016/j.radmp.2025.09.008
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing dosimetric performance of HyperArc for thyroid-associated ophthalmopathy radiotherapy

Hongli Yang, Ding Zhang, Hongtao Chen, Heli Zhong et al.
Radiation Medicine and Protection
Advanced Radiotherapy Techniques
article

Assessing dosimetric performance of HyperArc for thyroid-associated ophthalmopathy radiotherapy

Hongli Yang, Ding Zhang, Hongtao Chen, Heli Zhong, Juan Fan
article en

Abstract

To assess the dosimetric performance of HyperArc in comparison with coplanar volumetric modulated arc therapy (c-VMAT) and non-coplanar VMAT (nc-VMAT) in the radiotherapy of thyroid-associated ophthalmopathy (TAO). This retrospective study involved 10 patients with TAO who received radiotherapy at our center from December 2021 to December 2023. A single qualified physicist generated treatment plans using c-VMAT, nc-VMAT, and HyperArc techniques on the TrueBeam machine with the Eclipse treatment planning system. We compared the dosimetric parameters for target volumes and organs at risk (OARs) among these planning approaches. Monitor units (MUs) were also evaluated to assess beam efficiency and delivery effectiveness for each plan type. Compared to c-VMAT and nc-VMAT plans, HyperArc plans achieved the highest conformity index (CI), with increases of 3.35% ( t = 3.84, P = 0.004) and 4.05% ( t = 5.01, P = 0.001), respectively. They also achieved the lowest gradient index (GI), with decreases of 29.41% ( t = -10.41, P < 0.001) and 25.11% ( t = -5.55, P < 0.001), respectively, and the lowest R 50% , with decreases of 31.69% ( t = -11.74, P < 0.001) and 28.01% ( t = -5.50, P < 0.001), respectively. In terms of the dosimetric parameters of OARs, HyperArc plans produced the best results among the three types of plans. Furthermore, HyperArc plans reduced MUs by 31.39% ( t = -8.59, P < 0.001) and 20.60% ( t = -2.70, P = 0.024) compared to c-VMAT and nc-VMAT plans, respectively. This study compared c-VMAT, nc-VMAT, and HyperArc for the radiotherapy of TAO and demonstrated the superior dosimetric performance of HyperArc. HyperArc provided better dose conformity for targets, sharper dose falloff outside targets, more effective sparing of OARs, and more efficient utilization and delivery of rays.

Radiation Medicine and ProtectionVol. 6(5)
Jinan University (CN), Southern University of Science and Technology (CN)
Openalex Percentile: Top 67%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.