Time resolution study for a plastic scintillator detector prototype readout by SiPMs for cosmic rays

New planned and in-development experiments for direct cosmic ray detection in balloons or satellites use plastic scintillators readout by silicon photomultipliers (SiPMs) to provide timing information with resolutions in the order of picoseconds (ps)\,\cite{AMS-100, ALADINO}. This information is essential for triggering, vetoing, or particle identification. Due to the particularly harsh environmental conditions these experiments are exposed to, it is important to investigate how such conditions affect the performance of the detector, especially timing information. In this work, we tested experimentally the time resolution response of a prototype TOF counter for temperatures ranging from -20 to 20 degrees Celsius.

Authors

Publication Details

Published
2025-09-23
DOI
https://doi.org/10.22323/1.501.0045
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time resolution study for a plastic scintillator detector prototype readout by SiPMs for cosmic rays

J. Castillo Castellanos, S. Aguilar Salazar, Diego Mauricio Gomez Coral
Radiation Detection and Scintillator Technologies
article

Time resolution study for a plastic scintillator detector prototype readout by SiPMs for cosmic rays

J. Castillo Castellanos, S. Aguilar Salazar, Diego Mauricio Gomez Coral
article en

Abstract

New planned and in-development experiments for direct cosmic ray detection in balloons or satellites use plastic scintillators readout by silicon photomultipliers (SiPMs) to provide timing information with resolutions in the order of picoseconds (ps)\,\cite{AMS-100, ALADINO}. This information is essential for triggering, vetoing, or particle identification. Due to the particularly harsh environmental conditions these experiments are exposed to, it is important to investigate how such conditions affect the performance of the detector, especially timing information. In this work, we tested experimentally the time resolution response of a prototype TOF counter for temperatures ranging from -20 to 20 degrees Celsius.

Openalex Percentile: Top 67%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.