Quality Control Measures for Enhancing Confidence in Nanoscale <scp>IR</scp> Spectroscopy

Photo‐induced Force Microscopy (PiFM) is a nanoanalytical, surface‐sensitive new‐frontier technique that provides in situ infrared spectroscopy at a spatial resolution of ~ 5 nm 2 , which is approximately one billion times higher than traditional FTIR. These advantages led to significant discoveries in Earth and environmental sciences, as well as related disciplines. However, the high resolution and surface sensitivity of PiFM makes it highly susceptible to surface contamination. Factors such as sample preparation, handling and storage can introduce particulate and/or molecular layer contaminants, which may interfere with data analysis and lead to misinterpretation of results. In this study, we systematically investigated common laboratory materials, including gloves, mounting materials, polishing agents and storage solutions as potential sources of particulate and molecular contaminants and compiled a library of reference spectra available to all users of nano‐scale molecular analyses. Further, we determined the contaminant signatures of human skin and gloves on AFM substrates and provided recommendations for sample preparation, handling and storage as well as strategies for contamination mitigation to ensure better‐informed analysis of structurally and compositionally complex geological materials. We identified molecular and particulate contaminants through their specific IR absorption bands, and provide recommendations to selectively avoid or remove them, thereby improving the reliability of nanoscale molecular analyses by PiFM, ultimately increasing confidence in new discoveries.

Authors

Institutions

Publication Details

Journal
Geostandards and Geoanalytical Research
Published
2025-09-23
DOI
https://doi.org/10.1111/ggr.70014
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality Control Measures for Enhancing Confidence in Nanoscale IR Spectroscopy

Derek Nowak, Brett Knowles, Deyanira Cisneros‐Lazaro, Laura M. Otter et al.
Geostandards and Geoanalytical Research
Integrated Circuits and Semiconductor Failure Analysis
article

Quality Control Measures for Enhancing Confidence in Nanoscale IR Spectroscopy

Derek Nowak, Brett Knowles, Deyanira Cisneros‐Lazaro, Laura M. Otter, Jarosław Stolarski, Michael W. Förster, Jochen J. Brocks, Kushani Jayasoma
article en

Abstract

Photo‐induced Force Microscopy (PiFM) is a nanoanalytical, surface‐sensitive new‐frontier technique that provides in situ infrared spectroscopy at a spatial resolution of ~ 5 nm 2 , which is approximately one billion times higher than traditional FTIR. These advantages led to significant discoveries in Earth and environmental sciences, as well as related disciplines. However, the high resolution and surface sensitivity of PiFM makes it highly susceptible to surface contamination. Factors such as sample preparation, handling and storage can introduce particulate and/or molecular layer contaminants, which may interfere with data analysis and lead to misinterpretation of results. In this study, we systematically investigated common laboratory materials, including gloves, mounting materials, polishing agents and storage solutions as potential sources of particulate and molecular contaminants and compiled a library of reference spectra available to all users of nano‐scale molecular analyses. Further, we determined the contaminant signatures of human skin and gloves on AFM substrates and provided recommendations for sample preparation, handling and storage as well as strategies for contamination mitigation to ensure better‐informed analysis of structurally and compositionally complex geological materials. We identified molecular and particulate contaminants through their specific IR absorption bands, and provide recommendations to selectively avoid or remove them, thereby improving the reliability of nanoscale molecular analyses by PiFM, ultimately increasing confidence in new discoveries.

Geostandards and Geoanalytical ResearchVol. 49(4)
Australian National University (AU), Molecular Vista (United States) (US), Institute of Paleobiology (PL), École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 75%
Integrated Circuits and Semiconductor Failure Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.