Experimental tests of steel balcony connections – part 2

Paper presents theoretical analysis and results of experimental tests of three prefabricated balcony sets in natural scale with dimensions (width × length × height): 2.0 m × 2.78 m × 0.186 m (in a slope to 0.17 m) and one with dimensions: 2.0 m × 2.78 m × 0.2 m, consists of reinforced concrete slabs connected with each other with steel balcony connections. The impact of variable parameters (elongation of anchorage of balcony connections in ceiling slab, concreting of test elements in two stages, using of muffs as couplers to connect the longitudinal reinforcement bars in balcony sets and different height of the balcony slab) on the load bearing capacity of the elements are analysed. During the experimental tests deformations in the balcony connection using strain gauge sensors were measured. Global safety factor for all tested elements are determined. A numerical shell model of balcony connection is presented, validated using the results from experimental tests.

Authors

Institutions

Publication Details

Journal
Archives of Civil Engineering
Published
2025-09-22
DOI
https://doi.org/10.24425/ace.2025.155085
Primary Topic
Structural Engineering and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental tests of steel balcony connections – part 2

Maciej Niedostatkiewicz, Paweł Piotrkowski, Maciej Tomasz Solarczyk
Archives of Civil Engineering
Structural Engineering and Vibration Analysis
article

Experimental tests of steel balcony connections – part 2

Maciej Niedostatkiewicz, Paweł Piotrkowski, Maciej Tomasz Solarczyk
article en

Abstract

Paper presents theoretical analysis and results of experimental tests of three prefabricated balcony sets in natural scale with dimensions (width × length × height): 2.0 m × 2.78 m × 0.186 m (in a slope to 0.17 m) and one with dimensions: 2.0 m × 2.78 m × 0.2 m, consists of reinforced concrete slabs connected with each other with steel balcony connections. The impact of variable parameters (elongation of anchorage of balcony connections in ceiling slab, concreting of test elements in two stages, using of muffs as couplers to connect the longitudinal reinforcement bars in balcony sets and different height of the balcony slab) on the load bearing capacity of the elements are analysed. During the experimental tests deformations in the balcony connection using strain gauge sensors were measured. Global safety factor for all tested elements are determined. A numerical shell model of balcony connection is presented, validated using the results from experimental tests.

Archives of Civil Engineering
Gdańsk University of Technology (PL)
Openalex Percentile: Top 73%
Structural Engineering and Vibration Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.