Expansive soils as the root cause of a historic underground potable water reservoir failure

The paper describes the root causes of damage to an underground potable water reservoir. It is made of reinforced concrete and consists of two chambers founded on subsoil diversified for its age and origin (folds of glacitectonically disturbed septarian clays and postglacial loams). The documented damage results from subsoil deformation caused by volumetric changes in the ground (shrinkage and swelling) due to the facility’s exposure to various external factors determining the phenomenon’s intensity for over one hundred years. The analysed example presents problems arising from founding the facility on expansive soils. It highlights the hazards resulting from negligence in landscape architecture development and emphasises the role of identifying the subsoil. Comprehensive geotechnical examination and geophysical measurements of the structure and subsoil, making the inventory and evaluating the nature of the damage helped identify the potential factor detrimental to the facility’s technical condition. The conclusions are confirmed by numerical simulations, which include the impact of swelling and cyclic loads resulting from the facility’s function and surroundings.

Authors

Institutions

Publication Details

Journal
Archives of Civil Engineering
Published
2025-09-22
DOI
https://doi.org/10.24425/ace.2025.155114
Primary Topic
Grouting, Rheology, and Soil Mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Expansive soils as the root cause of a historic underground potable water reservoir failure

Radosław Mieszkowski, Tomasz Godlewski
Archives of Civil Engineering
Grouting, Rheology, and Soil Mechanics
article

Expansive soils as the root cause of a historic underground potable water reservoir failure

Radosław Mieszkowski, Tomasz Godlewski
article en

Abstract

The paper describes the root causes of damage to an underground potable water reservoir. It is made of reinforced concrete and consists of two chambers founded on subsoil diversified for its age and origin (folds of glacitectonically disturbed septarian clays and postglacial loams). The documented damage results from subsoil deformation caused by volumetric changes in the ground (shrinkage and swelling) due to the facility’s exposure to various external factors determining the phenomenon’s intensity for over one hundred years. The analysed example presents problems arising from founding the facility on expansive soils. It highlights the hazards resulting from negligence in landscape architecture development and emphasises the role of identifying the subsoil. Comprehensive geotechnical examination and geophysical measurements of the structure and subsoil, making the inventory and evaluating the nature of the damage helped identify the potential factor detrimental to the facility’s technical condition. The conclusions are confirmed by numerical simulations, which include the impact of swelling and cyclic loads resulting from the facility’s function and surroundings.

Archives of Civil Engineering
Building Research Institute (JP), University of Warsaw (PL)
Openalex Percentile: Top 73%
Grouting, Rheology, and Soil Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.