Recent advances in metal oxide, bimetallic nanocomposites, metal-organic frameworks (MOFs), and non-invasive technologies for biofluid-based glucose sensors: A comprehensive review

The field of glucose biosensors for diabetes control has experienced enormous scientific and technological developments since it was first introduced in the 1960s, with electrochemical biosensors emerging as the most promising platform for real-time, dynamic glucose monitoring due to the high precision, versatility and compatibility with wearable devices. Over the past decade, wearable healthcare technologies have significantly advanced, enabling non-invasive or minimally invasive monitoring of biomarkers in peripheral biofluids such as sweat, saliva, tears and interstitial fluid (ISF) through electrochemical sensing. While enzymatic biosensors, particularly those employing glucose oxidase (GOx), remain prevalent for their sensitivity, challenges such as enzyme instability and limited shelf life persist. In response, non-enzymatic have gained prominence, leveraging nanostructure materials like metal oxides (e.g., NiO, CuO, ZnO), metal-organic frameworks (MOFs) and bimetallic composites (e.g., CuCo-MOFs) to achieve superior sensitivity, stability and catalytic performance. These materials exploit high surface-to-volume ratios, tuneable porosity and synergistic effects to overcome limitations such as pH sensitivity and poor conductivity. Innovations in material design, including laser-induced (LIG) and hybrid composites (eg., MXene/rGO), further enhance electron transfer and these materials enable low detection limits, wide linear ranges and rapid response time. This review comprehensively examines recent enzyme-free glucose sensors, focusing on the advancement of nanomaterials and their integration into wearable platforms such as microneedle-based ISF monitor contact lens sensors for tear analysis and hydrogel patches for sweat glucose detection. We critically evaluate the current state of biofluid sensing, addressing challenges in accuracy mad scalability while highlighting the convergence of advanced nanomaterials.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2025-09-23
DOI
https://doi.org/10.1016/j.ijoes.2025.101184
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recent advances in metal oxide, bimetallic nanocomposites, metal-organic frameworks (MOFs), and non-invasive technologies for biofluid-based glucose sensors: A comprehensive review

Gentil Mwengula, Letta Ntuli, Jean Mulopo, Tshimangadzo S. Munonde et al.
2 citations
International Journal of Electrochemical Science
Electrochemical sensors and biosensors
1.46
article

Recent advances in metal oxide, bimetallic nanocomposites, metal-organic frameworks (MOFs), and non-invasive technologies for biofluid-based glucose sensors: A comprehensive review

Gentil Mwengula, Letta Ntuli, Jean Mulopo, Tshimangadzo S. Munonde, Alain Nyembwe
article en
2 citations

Abstract

The field of glucose biosensors for diabetes control has experienced enormous scientific and technological developments since it was first introduced in the 1960s, with electrochemical biosensors emerging as the most promising platform for real-time, dynamic glucose monitoring due to the high precision, versatility and compatibility with wearable devices. Over the past decade, wearable healthcare technologies have significantly advanced, enabling non-invasive or minimally invasive monitoring of biomarkers in peripheral biofluids such as sweat, saliva, tears and interstitial fluid (ISF) through electrochemical sensing. While enzymatic biosensors, particularly those employing glucose oxidase (GOx), remain prevalent for their sensitivity, challenges such as enzyme instability and limited shelf life persist. In response, non-enzymatic have gained prominence, leveraging nanostructure materials like metal oxides (e.g., NiO, CuO, ZnO), metal-organic frameworks (MOFs) and bimetallic composites (e.g., CuCo-MOFs) to achieve superior sensitivity, stability and catalytic performance. These materials exploit high surface-to-volume ratios, tuneable porosity and synergistic effects to overcome limitations such as pH sensitivity and poor conductivity. Innovations in material design, including laser-induced (LIG) and hybrid composites (eg., MXene/rGO), further enhance electron transfer and these materials enable low detection limits, wide linear ranges and rapid response time. This review comprehensively examines recent enzyme-free glucose sensors, focusing on the advancement of nanomaterials and their integration into wearable platforms such as microneedle-based ISF monitor contact lens sensors for tear analysis and hydrogel patches for sweat glucose detection. We critically evaluate the current state of biofluid sensing, addressing challenges in accuracy mad scalability while highlighting the convergence of advanced nanomaterials.

International Journal of Electrochemical ScienceVol. 20(11)
University of South Africa (ZA), University of the Witwatersrand (ZA)
Openalex Percentile: Top 15%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.