3D Tetrametallic Dendrite-Based Non-Enzymatic Sensor Coupled with a Smartphone Interface for GSH Quantification in Biological Fluids and Ex Vivo Rat Models

Non-enzymatic platforms, based on inorganic nanomaterials, are emerging as promising alternatives to traditional enzyme-based platforms in catalytic applications. Recently, fern or tree like metallic dendrites have attracted growing interest for detection of target analytes due to their distinctive hierarchical branched morphology. It imparts dendrites' large specific surface area and hence a multitude of catalytic centers. In light of its significant functional properties, we attempted to synthesize a tetrametallic dendrite-based non-enzymatic sensing platform for direct detection of glutathione (GSH), which plays a crucial role in maintaining a redox balance in living organisms. However, when the body is under oxidative stress, its level drops, resulting in several clinical manifestations in the body. Therefore, the quantification of GSH continues to be the central focus of investigation among researchers. This study aims to develop a stable 3D tetrametallic dendritic non-enzymatic interface, an efficient alternative to enzyme-based systems for sensitive detection of GSH. The sensor demonstrated exceptional analytical performance, possessing a wide linearity between 0.05 and 200,000 nM and an impressively low detection limit of 0.02 nM. The non-enzymatic sensor reliably detects GSH in human serum samples with recovery percentages ranging between 91.17% and 99.73%. The developed tetrametallic interface was further employed to evaluate GSH levels in a diquat-induced rat model using plasma and liver homogenate samples. The outcomes showed that with increasing time following diquat administration and with increasing dosage of diquat, oxidative stress intensifies, accompanied by a progressive depletion of GSH. Furthermore, the smartphone integration with a developed sensor is an extended functionality of the nanoelectronic platform. It has the potential to be deployed on-site since it automates data processing and distinguishes healthy from critically low GSH levels in real samples. The rapid on-chip fabrication within 15 min and its smartphone integration highlight the potential for automated tracking in point-of-care diagnosis.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-09-22
DOI
https://doi.org/10.1021/acsami.5c10664
Citations
4
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
2.07
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D Tetrametallic Dendrite-Based Non-Enzymatic Sensor Coupled with a Smartphone Interface for GSH Quantification in Biological Fluids and Ex Vivo Rat Models

Pranjal Chandra, Rohini Kumari, Obulapathi Ummadisetty, Supratim Mahapatra et al.
4 citations
ACS Applied Materials & Interfaces
Advanced Nanomaterials in Catalysis
2.07
article

3D Tetrametallic Dendrite-Based Non-Enzymatic Sensor Coupled with a Smartphone Interface for GSH Quantification in Biological Fluids and Ex Vivo Rat Models

Pranjal Chandra, Rohini Kumari, Obulapathi Ummadisetty, Supratim Mahapatra, Vinod Tiwari
article en
4 citations

Abstract

Non-enzymatic platforms, based on inorganic nanomaterials, are emerging as promising alternatives to traditional enzyme-based platforms in catalytic applications. Recently, fern or tree like metallic dendrites have attracted growing interest for detection of target analytes due to their distinctive hierarchical branched morphology. It imparts dendrites' large specific surface area and hence a multitude of catalytic centers. In light of its significant functional properties, we attempted to synthesize a tetrametallic dendrite-based non-enzymatic sensing platform for direct detection of glutathione (GSH), which plays a crucial role in maintaining a redox balance in living organisms. However, when the body is under oxidative stress, its level drops, resulting in several clinical manifestations in the body. Therefore, the quantification of GSH continues to be the central focus of investigation among researchers. This study aims to develop a stable 3D tetrametallic dendritic non-enzymatic interface, an efficient alternative to enzyme-based systems for sensitive detection of GSH. The sensor demonstrated exceptional analytical performance, possessing a wide linearity between 0.05 and 200,000 nM and an impressively low detection limit of 0.02 nM. The non-enzymatic sensor reliably detects GSH in human serum samples with recovery percentages ranging between 91.17% and 99.73%. The developed tetrametallic interface was further employed to evaluate GSH levels in a diquat-induced rat model using plasma and liver homogenate samples. The outcomes showed that with increasing time following diquat administration and with increasing dosage of diquat, oxidative stress intensifies, accompanied by a progressive depletion of GSH. Furthermore, the smartphone integration with a developed sensor is an extended functionality of the nanoelectronic platform. It has the potential to be deployed on-site since it automates data processing and distinguishes healthy from critically low GSH levels in real samples. The rapid on-chip fabrication within 15 min and its smartphone integration highlight the potential for automated tracking in point-of-care diagnosis.

ACS Applied Materials & InterfacesVol. 17(39)
Sensors (United States) (US), Center for Pain and the Brain (US), Indian Institute of Technology BHU (IN), Banaras Hindu University (IN)
Openalex Percentile: Top 12%
Advanced Nanomaterials in Catalysis
2.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.