The Pre-clinical Safety of Graphene-based Electrodes Implanted on Rat Cerebral Cortex

Graphene has emerged as a promising nanomaterial for brain-computer interface (BCI) applications due to its excellent electrical properties and biocompatibility. However, its long-term structural compatibility on the cerebral cortex requires further validation. This study assessed both functional compatibility and preservation of neural tissue architecture for graphene/parylene C composite electrodes implanted on the rat cortical surface, in accordance with ISO 10993-6 guideline weekly neurobehavioral assessments and comprehensive histopathological analyses were conducted for four weeks post-implantation. Our results revealed no significant differences in neurobehavioral outcomes between graphene-based and medical-grade silicone implants. Histopathological examination showed no noticeable inflammatory responses, changes in cellular morphology, myelination status, or neuronal degeneration. These findings indicate that graphene electrodes preserve tissue integrity comparable to medical‑grade silicone. Our study supports graphene's potential use in clinical neuroprosthetics and neuromodulation devices.

Authors

Institutions

Publication Details

Journal
Experimental Neurobiology
Published
2025-09-23
DOI
https://doi.org/10.5607/en25018
Citations
2
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
1.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Pre-clinical Safety of Graphene-based Electrodes Implanted on Rat Cerebral Cortex

Gaeun Kim, Sungchil Yang, B.K. Kim, Sunggu Yang et al.
2 citations
Experimental Neurobiology
Neuroscience and Neural Engineering
1.82
article

The Pre-clinical Safety of Graphene-based Electrodes Implanted on Rat Cerebral Cortex

Gaeun Kim, Sungchil Yang, B.K. Kim, Sunggu Yang, Eunha Baeg, Hyerin Jeong, Sangwon Lee, Kyung‐Tae Kim
article en
2 citations

Abstract

Graphene has emerged as a promising nanomaterial for brain-computer interface (BCI) applications due to its excellent electrical properties and biocompatibility. However, its long-term structural compatibility on the cerebral cortex requires further validation. This study assessed both functional compatibility and preservation of neural tissue architecture for graphene/parylene C composite electrodes implanted on the rat cortical surface, in accordance with ISO 10993-6 guideline weekly neurobehavioral assessments and comprehensive histopathological analyses were conducted for four weeks post-implantation. Our results revealed no significant differences in neurobehavioral outcomes between graphene-based and medical-grade silicone implants. Histopathological examination showed no noticeable inflammatory responses, changes in cellular morphology, myelination status, or neuronal degeneration. These findings indicate that graphene electrodes preserve tissue integrity comparable to medical‑grade silicone. Our study supports graphene's potential use in clinical neuroprosthetics and neuromodulation devices.

Experimental NeurobiologyVol. 34(5)
Incheon National University (KR), City University of Hong Kong (HK), Incheon Medical Center (KR)
Incheon National University
Openalex Percentile: Top 13%
Neuroscience and Neural Engineering
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Pre-clinical Safety of Graphene-based Electrodes Implanted on Rat Cerebral Cortex — Gaeun Kim, Sungchil Yang, et al. · Experimental Neurobiology (2025) | TGRS Research Map | TGRS