Evaluation of Operator Variability and Validation of an AI-Assisted α-Angle Measurement System for DDH Using a Phantom Model

Ultrasound examination using the Graf method is widely applied for early detection of developmental dysplasia of the hip (DDH), but intra- and inter-operator variability remains a limitation. This study aimed to quantify operator variability in hip ultrasound assessments and to validate an AI-assisted system for automated α-angle measurement to improve reproducibility. Thirty participants of different experience levels, including trained clinicians, residents, and medical students, each performed six ultrasound scans on a standardized infant hip phantom. Examination time, iliac margin inclination, and α-angle measurements were analyzed to assess intra- and inter-operator variability. In parallel, an AI-based system was developed to automatically detect anatomical landmarks and calculate α-angles from static images and dynamic video sequences. Validation was conducted using the phantom model with a known α-angle of 70°. Clinicians achieved shorter examination times and higher reproducibility than residents and students, with manual measurements systematically underestimating the reference α-angle. Static AI produced closer estimates with greater variability, whereas dynamic AI achieved the highest accuracy (mean 69.2°) and consistency with narrower limits of agreement than manual measurements. These findings confirm substantial operator variability and demonstrate that AI-assisted dynamic ultrasound analysis can improve reproducibility and reliability in routine DDH screening.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-09-22
DOI
https://doi.org/10.3390/bioengineering12091004
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Operator Variability and Validation of an AI-Assisted α-Angle Measurement System for DDH Using a Phantom Model

Tomohiro Shimizu, Yumejiro Nakamura, Norimasa Iwasaki, Hidenori Koyano et al.
Bioengineering
Hip disorders and treatments
article

Evaluation of Operator Variability and Validation of an AI-Assisted α-Angle Measurement System for DDH Using a Phantom Model

Tomohiro Shimizu, Yumejiro Nakamura, Norimasa Iwasaki, Hidenori Koyano, Yusuke Ohashi, Daisuke Takahashi, Katsuhisa Yamada
article en

Abstract

Ultrasound examination using the Graf method is widely applied for early detection of developmental dysplasia of the hip (DDH), but intra- and inter-operator variability remains a limitation. This study aimed to quantify operator variability in hip ultrasound assessments and to validate an AI-assisted system for automated α-angle measurement to improve reproducibility. Thirty participants of different experience levels, including trained clinicians, residents, and medical students, each performed six ultrasound scans on a standardized infant hip phantom. Examination time, iliac margin inclination, and α-angle measurements were analyzed to assess intra- and inter-operator variability. In parallel, an AI-based system was developed to automatically detect anatomical landmarks and calculate α-angles from static images and dynamic video sequences. Validation was conducted using the phantom model with a known α-angle of 70°. Clinicians achieved shorter examination times and higher reproducibility than residents and students, with manual measurements systematically underestimating the reference α-angle. Static AI produced closer estimates with greater variability, whereas dynamic AI achieved the highest accuracy (mean 69.2°) and consistency with narrower limits of agreement than manual measurements. These findings confirm substantial operator variability and demonstrate that AI-assisted dynamic ultrasound analysis can improve reproducibility and reliability in routine DDH screening.

BioengineeringVol. 12(9)
Sapporo Medical University (JP), Hokkaido University (JP)
Openalex Percentile: Top 59%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Operator Variability and Validation of an AI-Assisted α-Angle Measurement System for DDH Using a Phantom Model — Tomohiro Shimizu, Yumejiro Nakamura, et al. · Bioengineering (2025) | TGRS Research Map | TGRS