Mismatch Between Heat Exposure Risk and Blue-Green Exposure in Wuhan: A Coupled Spatial Analysis

Urban blue-green infrastructure (UBGI) has been recognized as an effective nature-based solution (NbS) for mitigating urban overheating through temperature reduction. However, there is a paucity of research examining whether UBGI spatial configurations align with the geographical distribution of the heat exposure risks of urban residents. This study focuses on this research gap, employing a population-weighted algorithm to conduct a refined assessment of the blue-green spaces exposure and heat exposure risks of urban residents. Then, the heat exposure risk was conceptualized as the demand for cooling services, with exposure to blue-green spaces serving as the supply. A comprehensive assessment was finally conducted of the supply–demand relationship and coupling coordination level for cooling services in central Wuhan. The following findings were revealed: (1) Both heat exposure risks and blue-green exposure demonstrate distinct “west high–east low” spatial gradients. It is evident that extreme high/high-risk zones, which encompass 17.1% of the study area, house 74.49% of the permanent population; (2) A substantial and pervasive positive correlation exists between UGBI exposure and the heat exposure risk. “High-demand–high-supply” areas (14.90% coverage) concentrate in urban cores, overlapping with 61.25% high-risk populations, while 0.29% of zones show “high-demand–low-supply” mismatches, revealing concentrated but ineffective UGBI distribution; (3) A pervasive supply–demand imbalance is evident, with 90.64% of regions exhibiting an unacceptable coupling type range (0 < D ≤ 0.4) and a mere 1.39% attaining an acceptable range (0.6 < D ≤ 1). These findings underscore the inadequacy of prevailing urban blue-green infrastructure configurations in addressing heat exposure risks. The construction of cities with greater heat resilience necessitates the implementation of multidimensional strategies aimed at risk mitigation.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-09-19
DOI
https://doi.org/10.3390/su17188440
Citations
1
Primary Topic
Urban Green Space and Health
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mismatch Between Heat Exposure Risk and Blue-Green Exposure in Wuhan: A Coupled Spatial Analysis

Ting Xia, Liwei Zhang, Yu Zou
1 citations
Sustainability
Urban Green Space and Health
1.20
article

Mismatch Between Heat Exposure Risk and Blue-Green Exposure in Wuhan: A Coupled Spatial Analysis

Ting Xia, Liwei Zhang, Yu Zou
article en
1 citations

Abstract

Urban blue-green infrastructure (UBGI) has been recognized as an effective nature-based solution (NbS) for mitigating urban overheating through temperature reduction. However, there is a paucity of research examining whether UBGI spatial configurations align with the geographical distribution of the heat exposure risks of urban residents. This study focuses on this research gap, employing a population-weighted algorithm to conduct a refined assessment of the blue-green spaces exposure and heat exposure risks of urban residents. Then, the heat exposure risk was conceptualized as the demand for cooling services, with exposure to blue-green spaces serving as the supply. A comprehensive assessment was finally conducted of the supply–demand relationship and coupling coordination level for cooling services in central Wuhan. The following findings were revealed: (1) Both heat exposure risks and blue-green exposure demonstrate distinct “west high–east low” spatial gradients. It is evident that extreme high/high-risk zones, which encompass 17.1% of the study area, house 74.49% of the permanent population; (2) A substantial and pervasive positive correlation exists between UGBI exposure and the heat exposure risk. “High-demand–high-supply” areas (14.90% coverage) concentrate in urban cores, overlapping with 61.25% high-risk populations, while 0.29% of zones show “high-demand–low-supply” mismatches, revealing concentrated but ineffective UGBI distribution; (3) A pervasive supply–demand imbalance is evident, with 90.64% of regions exhibiting an unacceptable coupling type range (0 < D ≤ 0.4) and a mere 1.39% attaining an acceptable range (0.6 < D ≤ 1). These findings underscore the inadequacy of prevailing urban blue-green infrastructure configurations in addressing heat exposure risks. The construction of cities with greater heat resilience necessitates the implementation of multidimensional strategies aimed at risk mitigation.

SustainabilityVol. 17(18)
China Land Surveying and Planning Institute (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 18%
Urban Green Space and Health
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.