Optimizing Perioperative Glycaemic Control with Continuous Glucose Monitoring in Pregestational Diabetes: Feasibility and Comparative Analysis of Two Systems: A Pilot Study

<b>Background:</b> Continuous glucose monitoring (CGM) has changed the clinical practice in diabetes management during pregnancy; however, its application during caesarean section remains understudied. This feasibility study evaluates the performance, reliability, and clinical utility of two CGM systems-FreeStyle Libre 2 and Medtronic Guardian Connect-during caesarean delivery and the early postpartum period in a patient with pregestational diabetes mellitus (PGDM). <b>Methods</b>: A prospective, single-patient study was conducted. A 32-year-old woman with type 1 diabetes underwent elective caesarean section at 38 weeks of gestation. Both CGM systems were applied over 18 h prior to surgery and monitored continuously through the intraoperative and five-day postpartum period. Glucose data, device performance, and usability were assessed. <b>Results</b>: Both CGM systems provided uninterrupted, high-quality glucose data throughout the perioperative period, including during spinal anaesthesia, surgical manipulation, and postoperative recovery. No sensor displacement nor signal loss occurred. Glycaemic readings remained within the normoglycaemic range (90-100 mg/dL) during surgery, with mild elevations observed during anaesthesia initiation. Postoperatively, both systems showed comparable glucose trends, with slightly lower readings from FreeStyle Libre 2. <b>Conclusions</b>: CGM is feasible and reliable during caesarean section in PGDM patients. These findings support the integration of CGM into obstetric surgical care and highlight the need for larger studies to validate clinical benefits.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-22
DOI
https://doi.org/10.3390/jcm14186670
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Perioperative Glycaemic Control with Continuous Glucose Monitoring in Pregestational Diabetes: Feasibility and Comparative Analysis of Two Systems: A Pilot Study

Paweł Bartnik, Aneta Malinowska-Polubiec, Aleksandra Urban, Joanna Kacperczyk‐Bartnik et al.
Journal of Clinical Medicine
Diabetes Management and Research
article

Optimizing Perioperative Glycaemic Control with Continuous Glucose Monitoring in Pregestational Diabetes: Feasibility and Comparative Analysis of Two Systems: A Pilot Study

Paweł Bartnik, Aneta Malinowska-Polubiec, Aleksandra Urban, Joanna Kacperczyk‐Bartnik, Jacek Sieńko, Krzysztof Czajkowski, Ewa Romejko-Wolniewicz, Aleksandra Bender, Piotr Świderczak
article en

Abstract

<b>Background:</b> Continuous glucose monitoring (CGM) has changed the clinical practice in diabetes management during pregnancy; however, its application during caesarean section remains understudied. This feasibility study evaluates the performance, reliability, and clinical utility of two CGM systems-FreeStyle Libre 2 and Medtronic Guardian Connect-during caesarean delivery and the early postpartum period in a patient with pregestational diabetes mellitus (PGDM). <b>Methods</b>: A prospective, single-patient study was conducted. A 32-year-old woman with type 1 diabetes underwent elective caesarean section at 38 weeks of gestation. Both CGM systems were applied over 18 h prior to surgery and monitored continuously through the intraoperative and five-day postpartum period. Glucose data, device performance, and usability were assessed. <b>Results</b>: Both CGM systems provided uninterrupted, high-quality glucose data throughout the perioperative period, including during spinal anaesthesia, surgical manipulation, and postoperative recovery. No sensor displacement nor signal loss occurred. Glycaemic readings remained within the normoglycaemic range (90-100 mg/dL) during surgery, with mild elevations observed during anaesthesia initiation. Postoperatively, both systems showed comparable glucose trends, with slightly lower readings from FreeStyle Libre 2. <b>Conclusions</b>: CGM is feasible and reliable during caesarean section in PGDM patients. These findings support the integration of CGM into obstetric surgical care and highlight the need for larger studies to validate clinical benefits.

Journal of Clinical MedicineVol. 14(18)
Medical University of Warsaw (PL)
Openalex Percentile: Top 65%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.