Early-Time Cement Stress Characterization using Conventional and Fiber-Optic Bragg Gratings

Summary Accurate characterization of early-time cement stress and behavior is essential for assessing wellbore integrity. Fiber Bragg grating (FBG) technology offers a robust solution for deployment in hostile downhole environments, where conventional strain gauge measurements are often infeasible. For this study, we designed a measurement strategy and validated the accuracy of FBG fibers for early-time downhole cement assessment under simulated laboratory conditions. A steel pipe and water/cement assembly were used to mimic the downhole cement curing process under controlled stress conditions. Using water as the testing material, we validated the accuracy of FBG technology and quantified its uncertainties, achieving an expected error of approximately 2%, which is even smaller than the expected error of 5% for conventional strain gauge measurements in the current tests. Both FBG and strain gauge measurements exhibited drift, although they manifested differently. While the FBG measurement drift diverged with loading history, the averaged FBG measurements remained accurate, which offers valuable insight into long-term deployment viability and suggests how to design robust field systems. In the cement tests, we observed the typical exponential decrease in early-time radial stress during cement setting. With a 20-MPa hydrostatic pressure, cement initial stress decreased to 6.5–8.3 MPa after 2,500–4,900 minutes. Additionally, the cement tests highlighted the influence of temperature on both strain gauge and FBG measurements. Results from this study demonstrate the advantages and accuracy of FBG technology for downhole wellbore integrity assessment and cement stress characterization, which could support the earlier detection of cement integrity issues and help reduce long-term intervention costs.

Authors

Institutions

Publication Details

Journal
SPE Journal
Published
2025-09-22
DOI
https://doi.org/10.2118/230313-pa
Citations
1
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early-Time Cement Stress Characterization using Conventional and Fiber-Optic Bragg Gratings

Hyeyoung Koh, K. C. Bijay, Qiquan Xiong, Carly M. Donahue et al.
1 citations
SPE Journal
Advanced Fiber Optic Sensors
0.73
article

Early-Time Cement Stress Characterization using Conventional and Fiber-Optic Bragg Gratings

Hyeyoung Koh, K. C. Bijay, Qiquan Xiong, Carly M. Donahue, Luke Frash, Meng Meng
article en
1 citations

Abstract

Summary Accurate characterization of early-time cement stress and behavior is essential for assessing wellbore integrity. Fiber Bragg grating (FBG) technology offers a robust solution for deployment in hostile downhole environments, where conventional strain gauge measurements are often infeasible. For this study, we designed a measurement strategy and validated the accuracy of FBG fibers for early-time downhole cement assessment under simulated laboratory conditions. A steel pipe and water/cement assembly were used to mimic the downhole cement curing process under controlled stress conditions. Using water as the testing material, we validated the accuracy of FBG technology and quantified its uncertainties, achieving an expected error of approximately 2%, which is even smaller than the expected error of 5% for conventional strain gauge measurements in the current tests. Both FBG and strain gauge measurements exhibited drift, although they manifested differently. While the FBG measurement drift diverged with loading history, the averaged FBG measurements remained accurate, which offers valuable insight into long-term deployment viability and suggests how to design robust field systems. In the cement tests, we observed the typical exponential decrease in early-time radial stress during cement setting. With a 20-MPa hydrostatic pressure, cement initial stress decreased to 6.5–8.3 MPa after 2,500–4,900 minutes. Additionally, the cement tests highlighted the influence of temperature on both strain gauge and FBG measurements. Results from this study demonstrate the advantages and accuracy of FBG technology for downhole wellbore integrity assessment and cement stress characterization, which could support the earlier detection of cement integrity issues and help reduce long-term intervention costs.

SPE JournalVol. 30(11)
Los Alamos National Laboratory (US), Washington State University (US)
Openalex Percentile: Top 23%
Advanced Fiber Optic Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.